Evidence map›Paper›PMID 40931540›Full record

ArticleMagnetic resonance in medicine2026

Few-shot learning for highly accelerated 3D time-of-flight MRA reconstruction.

Hao Li, Mark Chiew, Iulius Dragonu, Peter Jezzard, Thomas W Okell

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hao LiCentre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.ORCID 0000-0003-2476-0664
Mark ChiewPhysical Sciences, Sunnybrook Research Institute, Toronto, Ontario, Canada.ORCID 0000-0001-6272-8783
Iulius DragonuResearch & Collaborations GB&I, Siemens Healthcare Ltd, Camberley, UK.
Peter JezzardCentre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.ORCID 0000-0001-7912-2251
Thomas W OkellCentre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.ORCID 0000-0001-8258-0659

Funding

Canada Research ChairsMedical Research CouncilNIHR Oxford Biomedical Research Centre NIHR203311NIHR Oxford Health Biomedical Research Centre NIHR203316Siemens HealthineersVivensa FoundationWellcome TrustWellcome Trust 203139/A/16/ZWellcome Trust 203139/Z/16/ZWellcome Trust 220204/Z/20/Z
6 · The paper itself

Abstract

purposeTo develop a deep learning-based reconstruction method for highly accelerated 3D time-of-flight MRA (TOF-MRA) that achieves high-quality reconstruction with robust generalization using extremely limited acquired raw data, addressing the challenge of time-consuming acquisition of high-resolution, whole-head angiograms.

methodsA novel few-shot learning-based reconstruction framework is proposed, featuring a 3D variational network specifically designed for 3D TOF-MRA that is pre-trained on simulated complex-valued, multi-coil raw k-space datasets synthesized from diverse open-source magnitude images and fine-tuned using only two single-slab experimentally acquired datasets. The proposed approach was evaluated against existing methods on acquired retrospectively undersampled in vivo k-space data from five healthy volunteers and on prospectively undersampled data from two additional subjects.

resultsThe proposed method achieved superior reconstruction performance on experimentally acquired in vivo data over comparison methods, preserving most fine vessels with minimal artifacts with up to eight-fold acceleration. Compared to other simulation techniques, the proposed method generated more realistic raw k-space data for 3D TOF-MRA. Consistently high-quality reconstructions were also observed on prospectively undersampled data.

conclusionsBy leveraging few-shot learning, the proposed method enabled highly accelerated 3D TOF-MRA relying on minimal experimentally acquired data, achieving promising results on both retrospective and prospective in vivo data while outperforming existing methods. Given the challenges of acquiring and sharing large raw k-space datasets, this holds significant promise for advancing research and clinical applications in high-resolution, whole-head 3D TOF-MRA imaging.

Indexed as

Deep LearningImage Processing, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance AngiographyAdultAlgorithmsArtifactsBrainHeadHealthy VolunteersHumansMaleRetrospective Studiesdata synthesisdeep learningfew‐shot learningimage reconstructionmagnetic resonance angiographytime‐of‐flight

Identifiers

PMID40931540
PMCPMC12681298

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.