ArticleShoulder & elbow2025
Ultrasound shear wave elastography - a reliable protocol for the assessment of the stiffness of the supraspinatus tendon.
Article in Shoulder & elbow, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: The continued evolution of shear wave elastography (SWE) in the measurement of supraspinatus tendon stiffness can assist in both rehabilitation and surgical monitoring with the potential to improve patient outcomes. It can provide non-invasive, quantitative data of elastic properties of tendons which are altered in the presence of pathological change. This study evaluates the inter- and intra-rater reliability of a standardised SWE assessment protocol of the supraspinatus tendon. Methods: Shear wave velocity (SWV, m/s) values of 52 healthy, asymptomatic supraspinatus tendons were recorded using SWE. Two raters scanned each tendon on two separate occasions, seven days apart, using a strict protocol. Results: Intraclass correlation coefficient (ICC) for inter-rater reliability was 0.78. Intra-rater reliability was 0.81 for rater one and 0.89 for rater two, respectively. Minimal detectable change (MDC Conclusion: The results demonstrate reliable SWV measurements between and within raters in the supraspinatus tendon, providing normative values and a protocol which may be utilised clinically.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.