Evidence map›Paper›PMID 40988073›Full record

ArticleBMC chemistry2025

Development and validation of a sustainable spectrofluorimetric method for simultaneous quantification of amlodipine and aspirin using genetic algorithm-enhanced partial least squares regression.

Taha Alqahtani, Ali Alqahtani, Ahmed A Almrasy

Abstract read
In one paragraph

Article in BMC chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Taha AlqahtaniDepartment of Pharmacology, College of Pharmacy, King Khalid University, Abha, 62529, Saudi Arabia.
Ali AlqahtaniDepartment of Pharmacology, College of Pharmacy, King Khalid University, Abha, 62529, Saudi Arabia.
Ahmed A AlmrasyPharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Al-Azhar University, Cairo, 11751, Egypt. ahmedalialmrasy8@gmail.com.

Funding

Deanship of Research and Graduate Studies at King Khalid University RGP 2/413/46
6 · The paper itself

Abstract

The widespread clinical utilization of amlodipine-aspirin combinations, despite potential pharmacodynamic interactions and the high prevalence of drug-drug interactions in cardiovascular patients, necessitates robust analytical methods for pharmaceutical quality control and therapeutic drug monitoring. Current analytical approaches face limitations including lengthy analysis times, substantial solvent consumption, and high operational costs. This study presents a novel spectrofluorimetric method coupled with genetic algorithm-enhanced partial least squares (GA-PLS) regression for simultaneous quantification of amlodipine and aspirin in pharmaceutical formulations and biological plasma samples. Synchronous fluorescence spectroscopy at Δλ = 100 nm in 1% sodium dodecyl sulfate-ethanolic medium enhanced spectral characteristics, while chemometric approaches were essential to address remaining spectral overlap for accurate quantification. The GA-PLS approach demonstrated superior performance over conventional partial least squares regression, achieving relative root mean square errors of prediction (RRMSEP) of 0.93 and 1.24 for amlodipine and aspirin respectively, with limits of detection of 22.05 and 15.15 ng/mL. Genetic algorithm optimization reduced spectral variables to approximately 10% of the original dataset while maintaining optimal model performance with only two latent variables. Method validation according to ICH Q2(R2) guidelines demonstrated excellent accuracy (98.62-101.90% recovery) and precision (RSD < 2%) across the analytical range of 200-800 ng/mL. Statistical comparison with established HPLC reference methods showed no significant differences, while application in human plasma achieved recoveries of 95.58-104.51% with coefficient of variation below 5%. Multi-dimensional sustainability assessment using the MA Tool and RGB12 whiteness evaluation achieved an overall score of 91.2%, demonstrating clear superiority over conventional HPLC-UV (83.0%) and LC-MS/MS (69.2%) methods across environmental, analytical, and practical dimensions. The developed method provides a sustainable, cost-effective alternative for routine pharmaceutical analysis, demonstrating enhanced performance through intelligent variable selection and improved operational efficiency.

Indexed as

AmlodipineAspirinChemometricsGenetic algorithmSpectrofluorimetry

Identifiers

PMID40988073
PMCPMC12455781

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.