Evidence map›Paper›PMID 41015857›Full record

ArticleKorean journal of radiology2025

Deep Learning-Based Breath-Hold and Free-Breathing Cine MRI for Comprehensive Cardiac Evaluation.

Yali Wu, Wei Sun, Shiyu Wang, Xianling Qian, Qingqing Wen, Guifeng Fu, Hang Jin, Lin Tian, Yinyin Chen, Mengsu Zeng

Abstract read
In one paragraph

Article in Korean journal of radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Yali Wu *Shanghai Institute of Medical Imaging, Shanghai, China.ORCID https://orcid.org/0009-0005-6650-402X
Wei Sun *Shanghai Institute of Medical Imaging, Shanghai, China.ORCID https://orcid.org/0000-0002-0923-6760
Shiyu WangShanghai Institute of Medical Imaging, Shanghai, China.ORCID https://orcid.org/0009-0007-5374-0087
Xianling QianShanghai Institute of Medical Imaging, Shanghai, China.ORCID https://orcid.org/0000-0001-5366-4976
Qingqing WenMR Research, GE Healthcare, Beijing, China.ORCID https://orcid.org/0000-0001-5750-9279
Guifeng FuMR Research, GE Healthcare, Beijing, China.ORCID https://orcid.org/0009-0001-7696-4418
Hang JinShanghai Institute of Medical Imaging, Shanghai, China.ORCID https://orcid.org/0000-0002-6810-2527
Lin TianCircle Cardiovascular Imaging Inc., Calgary, Canada.ORCID https://orcid.org/0009-0002-4729-7238
Yinyin ChenShanghai Institute of Medical Imaging, Shanghai, China.ORCID https://orcid.org/0000-0002-1192-671X
Mengsu ZengShanghai Institute of Medical Imaging, Shanghai, China.ORCID https://orcid.org/0000-0001-6107-3623

Funding

Fujian Provincial Natural Science Foundation of China 2022J05333Joint Research Development Project between Shenkang and United Imaging on Clinical Research and Translation SKLY2022CRT201Shanghai Pujiang Program 21PJD012
6 · The paper itself

Abstract

objectiveTo evaluate and compare scan times, measurement accuracy, and image quality (IQ) of free-breathing (FB) and breath-hold (BH) deep learning (DL) cine MRI sequences versus standard cine MRI, with a specific focus on patients with arrhythmia and dyspnea. MATERIALS AND

methodsSeventy participants were prospectively enrolled, including 24 with arrhythmia, 17 with dyspnea, and 29 with normal sinus rhythm and eupnea (mean age, 49 ± 17 years). Each patient underwent three cine MRI acquisitions (standard cine, BHDL, and FBDL) on a 3T scanner. Quantitative assessments of biventricular function, left ventricular mass, and myocardial strain were independently performed by three radiologists, blinded to image acquisition techniques. IQ was evaluated by the same readers using both a five-point Likert scale and objective metrics.

resultsBoth BHDL and FBDL significantly reduced total examination times compared to standard cine (BHDL: 58 ± 5 s; FBDL: 88 ± 12 s; standard cine: 208 ± 12 s; adjusted

conclusionBoth FBDL and BHDL significantly reduced scan times compared to standard cine without compromising quantitative measurement accuracy. BHDL offered superior measurement accuracy and shorter scan time than FBDL. Furthermore, BHDL demonstrated robust suitability for patients with arrhythmia by minimizing arrhythmia-related artifacts, whereas FBDL was more effective in patients with dyspnea by mitigating respiratory motion artifacts.

Indexed as

Arrhythmias, CardiacBreath HoldingDeep LearningHeartMagnetic Resonance Imaging, CineAdultAgedDyspneaFemaleHumansImage Interpretation, Computer-AssistedMaleMiddle AgedProspective StudiesArrhythmiaCine cardiac MRDeep learningDyspneaImage reconstruction

Identifiers

PMID41015857
PMCPMC12479228

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.