Evidence map›Paper›PMID 41065828›Full record

Trial reportAbdominal radiology (New York)2026

Randomized trial of biopsy needle sandblasting in coaxial core-needle liver biopsy: no significant improvement in ultrasound visibility, pain, or tissue yield.

Masoud Pezeshki Rad, Maryam Ghandhari, Armin Doostparast, Maryam Emadzadeh, Amir Hossein Khosronejad, Alireza Khazen

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Abdominal radiology (New York), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Masoud Pezeshki RadDepartment of Radiology, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Islamic Republic of Iran.
Maryam GhandhariDepartment of Radiology, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Islamic Republic of Iran.
Armin DoostparastStudent Research Committee, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Islamic Republic of Iran. armindoostparast7@gmail.com.
Maryam EmadzadehClinical Research Development Unit, Ghaem Hospital, Mashhad University of Medical Sciences, Mashhad, Islamic Republic of Iran.
Amir Hossein KhosronejadStudent Research Committee, Mazandaran University of Medical Sciences, Sari, Islamic Republic of Iran.
Alireza KhazenDepartment of Radiology, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Islamic Republic of Iran. alireza.khazen57@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeOptimizing biopsy needle design could enhance procedural performance and patient comfort during core-needle liver biopsy (CNLB). This study aimed to compare a modified biopsy needle with a conventional one in terms of ultrasound visibility, patient-reported pain intensity, and diagnostic tissue yield.

methodsIn this randomized, triple-blind clinical trial, 70 adult patients scheduled for CNLB at Imam Reza Hospital (Mashhad, Iran) were enrolled and randomly assigned to either a conventional or modified needle group, both of which were commercially available. The modified needle was manufactured by doubling the sandblasting duration, which increased surface roughness and tip sharpness (2.74 to 5.28 Newtons). Pain intensity was measured using the Visual Analogue Scale (VAS) at four time points: during the procedure, 10 min after, 30 min after, and at discharge. The ultrasound visibility and the number of portal tracts in biopsy specimens were assessed independently. Patients requiring intravenous analgesics due to severe pain were excluded from further analysis.

results33 participants in the conventional biopsy needle group and 34 in the modified biopsy needle group completed all evaluations. There were no significant differences between groups in terms of age (P = 0.85), sex (P = 0.38), biopsy indication (P = 0.50), ultrasound visibility (P = 0.12), pain intensity at any time point (P > 0.05), and the number of portal tracts in biopsy specimens (P = 0.74). Despite the non-significant differences, both groups demonstrated low pain scores.

conclusionThe modified biopsy needle showed no significant improvement over the conventional needle regarding visibility, patient pain, and tissue adequacy. Therefore, the choice between biopsy needles remains a matter of clinical preference, user familiarity, and cost-effectiveness rather than significant differences in performance.

trial registrationIRCT20250422065439N1.

Indexed as

Image-Guided BiopsyLiverNeedlesProcedural PainUltrasonography, InterventionalAdultAgedBiopsy, Large-Core NeedleEquipment DesignFemaleHumansMaleMiddle AgedPain MeasurementCoaxial liver biopsyModified needlePainTissue adequacyUltrasound visibility

Identifiers

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.