Evidence map›Paper›PMID 41114067›Full record

ArticleJournal of cardiovascular echography

Contemporary Management of Cleaning and Disinfection Processes for Echocardiographic Equipment and Probes: National Real-world Data from an Italian Society of Echocardiography and Cardiovascular Imaging Survey.

Giuseppe Trocino, Andrea Barbieri, Quirino Ciampi, Francesca Mantovani, Agata Barchitta, Giorgio Faganello, Sofia Miceli, Vito Maurizio Parato, Francesco Antonini-Canterin, Scipione Carerj and 2 more

Abstract read
In one paragraph

Article in Journal of cardiovascular echography. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Giuseppe Trocino *Department of Non Invasive Cardiac Imaging, IRCCS Foundation San Gerardo dei Tintori, Monza, Italy.
Andrea Barbieri *Department of Biomedical, Metabolic and Neural Sciences, Cardiology Division, Modena Polyclinic, University of Modena and Reggio Emilia, Modena, Italy.
Quirino CiampiCardiology Division, Fatebenefratelli Hospital, Benevento, Italy.
Francesca MantovaniCardiology Division, Azienda USL - IRCCS di Reggio Emilia, Reggio Emilia, Italy.
Agata BarchittaScrivi il tuo dipartimento, Semi-intensive Care Unit, Padova University Hospital, Padua, Italy.
Giorgio FaganelloSemi-Intensive Care Department, Padova University Hospital, Padova, Italy.
Sofia MiceliDepartment of Medical and Surgical Sciences, University Magna Græcia of Catanzaro, Campus Universitario di Germaneto, Catanzaro, Italy.
Vito Maurizio ParatoCardiology Division, Madonna Del Soccorso Hospital, San Benedetto del Tronto (AP), Italy.
Francesco Antonini-CanterinDepartment of Rehabilitative Cardiology, Rehabilitative Hospital High Speciality, Motta di Livenza, Treviso, Italy.
Scipione CarerjCardiology Division, University Hospital Polyclinic G. Martino, University of Messina, Messina, Italy.
Mauro PepiCardiology Division, Monzino Cardiology Center, IRCCS, Milan, Italy.
Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI)

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Effective hygiene practices are crucial to mitigate infection risks in echocardiographic procedures. We conducted a nationwide survey to assess real-world disinfection standards in Italian echocardiography laboratories, measure adherence to core hygiene indicators, and identify structural determinants of compliance. Methods: A 35-item questionnaire was distributed to 331 accredited centers. Compliance was defined as adherence to ≥5 of 7 core hygiene indicators. Multivariable logistic regression identified predictors of high compliance. Results: Glove use (92.7%) and probe sheathing (34%-38%) were common, but high-level disinfection (HLD) remained underused (38.2% for surface probes and 64.7% for transesophageal echocardiography [TEE] probes). Only 48.3% of centers had traceability for TEE probe cleaning. Overall, 43.8% of centers achieved high compliance. Independent predictors included female gender (odds ratio [OR]: 2.37, 95% confidence interval [CI]: 1.49-3.75), hospital setting (OR: 2.50, 95% CI: 1.22-5.12), and high procedural volume (OR: 2.32, 95% CI: 1.45-3.71). Compliance varied by care setting, with outpatient clinics generally showing better adherence than emergency and intensive care units. Conclusions: Significant heterogeneity exists in disinfection practices across Italian echo laboratories, with persistent gaps in HLD, traceability, and environmental hygiene. Compliance was driven by operator characteristics and center-level factors rather than general institutional policies. These findings call for workflow-integrated protocols and targeted training to ensure standardized practice.

Indexed as

Advanced echocardiography imagingnational surveytechnologies

Identifiers

PMID41114067
PMCPMC12530722

What Socratic holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.