ArticleJournal of vascular surgery cases and innovative techniques2025
Needle-free vascular access port for hemodialysis: Proof-of-concept validation in an experimental animal study.
Article in Journal of vascular surgery cases and innovative techniques, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Vascular Access 4.0 for Hemodialysis: Toward a Needle-Free, Smart, Closed, and Connected System.Journal of clinical medicine · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Vascular access remains a critical challenge in kidney replacement therapy. Although arteriovenous fistulas are the reference standard, they are often compromised by maturation failure, complications, and repeated needling, which causes pain and distress for patients. A needle-free alternative could enhance safety, simplify use, and improve the patient experience, particularly in self-care and home dialysis. We evaluated the Safe Hemodialysis Implantable Vascular Access Technology arteriovenous port, a patented titanium device incorporating a twist-lock system anastomosed to a vascular graft prosthesis. The proof-of-concept study included in vitro testing to assess flow performance, durability, and hemocompatibility, followed by implantation in two sheep to determine surgical feasibility, hemodynamic function, and safety during a sham hemodialysis session. Implantation was successful without complications, the twist-lock system functioned securely, and no blood leakage, arterial bleeding, or air embolism occurred. The device provided adequate blood flow, although refinements are required to achieve clinical targets of 300-400 mL/min. These preliminary findings suggest that the Safe Hemodialysis Implantable Vascular Access Technology port is a feasible and safe needle-free vascular access concept, with potential to reduce needling burden, improve handling, and minimize infection risk in clinical use.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.