Evidence map›Paper›PMID 41187169›Full record

ArticlePloS one2025

Photophysical image analysis for sCMOS cameras: Noise modelling and estimation of background parameters in fluorescence-microscopy images.

Dibyajyoti Mohanta, Radhika Nambannor Kunnath, Erik Clarkson, Albertas Dvirnas, Fredrik Westerlund, Tobias Ambjörnsson

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Dibyajyoti MohantaCentre for Environmental and Climate Science, Lund University, Lund, Sweden.ORCID https://orcid.org/0000-0002-0118-6965
Radhika Nambannor KunnathDepartment of Life Sciences, Chalmers University of Technology, Gothenburg, Sweden.
Erik ClarksonCentre for Environmental and Climate Science, Lund University, Lund, Sweden.
Albertas DvirnasCentre for Environmental and Climate Science, Lund University, Lund, Sweden.ORCID https://orcid.org/0000-0002-1393-3024
Fredrik WesterlundDepartment of Life Sciences, Chalmers University of Technology, Gothenburg, Sweden.
Tobias AmbjörnssonCentre for Environmental and Climate Science, Lund University, Lund, Sweden.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Fluorescence microscopy is an effective tool for imaging biological samples, yet captured images often contain noises, including photon shot noise and camera read noise. To analyze biological samples accurately, separating background pixels from signal pixels is crucial. This would ideally be guided by the knowledge of a parameter called the Poisson parameter, [Formula: see text], representing the mean number of photons collected in a background pixel (for the case when quantum efficiency = 1 and the dark current is negligible). This study introduces a method for estimating [Formula: see text], from an image which contains both background and signal pixels, using probabilistic noise modeling for an sCMOS camera. The approach incorporates Poisson-distributed photon shot noise and sCMOS camera read noise modelled with a Tukey-Lambda distribution. We apply a chi-square test and a truncated fit technique to estimate [Formula: see text] directly from a general sCMOS image, with camera parameters determined through calibration experiments. We validate our method by comparing [Formula: see text] estimates in images captured by sCMOS and EMCCD cameras for the same field of view. Our analysis shows strong agreement for low to moderate exposure images, where estimated values for [Formula: see text] align well between the sCMOS and EMCCD images. Based on our estimated [Formula: see text], we perform image thresholding and segmentation using our previously introduced procedure. Our publicly available software provides a platform for photophysical image analysis for sCMOS camera systems.

Indexed as

Image Processing, Computer-AssistedMicroscopy, FluorescencePhotonsSignal-To-Noise Ratio

Identifiers

PMID41187169
PMCPMC12585066

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.