Evidence map›Paper›PMID 41267181›Full record

ArticleMedical physics2025

Impact of a prototype, dedicated AI-based spectral image reconstruction algorithm on the quality of low-keV virtual monoenergetic images and iodine maps: A phantom study.

Joël Greffier, Djamel Dabli, Maxime Pastor, Nicolas Rossetto, Elodie Dhombres, Philippe Coulon, Jean-Paul Beregi

Abstract read
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Joël GreffierIMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France.
Djamel DabliIMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France.
Maxime PastorIMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France.
Nicolas RossettoPhilips Healthcare, Suresnes, France.
Elodie DhombresIMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France.
Philippe CoulonPhilips Healthcare, Suresnes, France.
Jean-Paul BeregiIMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRecently, CT manufacturers have developed deep-learning-based reconstruction (DLR) algorithms for conventional and spectral CT images. On dual-energy CT platforms, DLR algorithms have been developed in particular to reduce image noise in virtual monoenergetic images (VMIs), and to improve the accuracy of iodine concentrations on iodine maps. PURPOSE: To assess the impact of a prototype, dedicated Spectral AI Reconstruction (SAIR) algorithm (Spectral Precise Image; Philips Healthcare) compared with a hybrid iterative reconstruction (HIR) algorithm ("Spectral", Philips Healthcare) on the quality of low-keV VMIs and iodine maps in abdomen-pelvis CT conditions.

methodsA spectral phantom was scanned on the dual-layer spectral CT system at 120 kVp and a CTDI

resultsFor all keV, noise magnitude values were higher than with HIR using the Sharp (11.9 ± 5.6%; p > 0.05) and Sharper (39.3 ± 7.3%; p = 0.004) levels and lower than HIR for the other SAIR levels, decreasing from Standard (-15.3 ± 3.9%; p > 0.05) to Smooth (-42.3 ± 2.2%; p = 0.004) and Smoother levels (-70.5 ± 1.1%; p < 0.001). For all energy levels, f

conclusionCompared to the HIR algorithm used in clinical practice for low-keV VMIs, Standard, Smooth and Smoother levels of SAIR reduced image noise and improved the detectability of contrast-enhanced lesions. Better noise texture was found only with the Standard and Smooth levels compared to HIR.

Indexed as

AlgorithmsDeep LearningImage Processing, Computer-AssistedIodinePhantoms, ImagingTomography, X-Ray ComputedHumansSignal-To-Noise RatioIodinecomputed tomographydeep‐learning image reconstructiondual‐energyimage qualitytask‐based image quality assessment

Identifiers

PMID41267181
PMCPMC12635434

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.