Evidence map›Paper›PMID 41267909›Full record

ArticleIEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division2025

Portable and Versatile Catheter Robot for Image-Guided Cardiovascular Interventions.

Nikhil Tej Kantu, Weibo Gao, Nitin Srinivasan, Gregory D Buckner, Hao Su

Abstract read
In one paragraph

Article in IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Nikhil Tej KantuDepartment of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695 USA.ORCID 0009-0005-1585-8215
Weibo GaoDepartment of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695 USA.ORCID 0009-0006-5138-7040
Nitin SrinivasanDepartment of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695 USA.
Gregory D BucknerDepartment of Mechanical and Aerospace Engineering, Joint NCSU/UNC Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695 USA, and also with the University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 USA.ORCID 0000-0002-6601-4814
Hao SuDepartment of Mechanical and Aerospace Engineering, Joint NCSU/UNC Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695 USA, and with the University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 USA, and also with the Biomechatronics and Intelligent Robotics Lab, Tandon School of Engineering, New York University, Brooklyn, NY 11201 USA.ORCID 0000-0003-3299-7418

Funding

SCH: Versatile and Compact Telerobot with Haptic Feedback and Physics-Informed Simulation for Safety Enhanced Neurovascular InterventionsR01NS141171 · NINDS · NORTH CAROLINA STATE UNIVERSITY RALEIGH · PI SU, HAO · 2024 to 2024
$295k
AHRQ HHS R18 HS029124NINDS NIH HHS R01 NS141171
6 · The paper itself

Abstract

Cardiovascular disease remains the primary cause of death worldwide, necessitating the development of advanced endovascular instruments and procedures. These interventional procedures typically involve the use of guide catheters and guidewires, which are navigated through the vasculature under X-ray guidance. However, these procedures expose clinicians to prolonged radiation, posing potential health risks. Recent advances in endovascular catheter robots can mitigate the aforementioned risks by allowing teleoperation, but procedural efficacy has been hindered by their bulky designs that require designated facilities. In addition, these robots have limited compatibility with a wide range of instrument types and diameters, restricting their applicability to specific clinical interventions. To address these unmet needs, we have designed, fabricated, and experimentally validated a portable and versatile 4 degree-of-freedom catheter robot that can manipulate commercially available cardiovascular instruments with diameters ranging from 1 to 9 F. Furthermore, we analytically modeled the drive mechanism of the catheter robot and evaluated its tracking and insertion force and torque performance through experiments. Our portable robot (250 mm × 350 mm × 250 mm) is approximately 90% smaller than most state-of-the-art systems, e.g., Siemens Corindus system (1780 mm × 690 mm × 1170 mm), thanks to our highly integrated direct drive motors, mechatronics design, and modular instrument routing. Experimental evaluations confirm that the robot can actuate guidewires and guide catheters at clinically relevant force and torque amplitudes, speeds, and bandwidths without risking damage to delicate vascular tissues. The clinical potential of our catheter robot is demonstrated by performing a simulated percutaneous coronary intervention using a 3-D-printed model of the human heart. The portability and versatility of this catheter robot make it applicable to a wide range of cardiovascular procedures to potentially facilitate effective treatments.

Indexed as

Cardiovascular interventioncatheterendovascular diseasefriction wheel driveportableroboticsversatile

Identifiers

PMID41267909
PMCPMC12629629

What Socratic holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.