Evidence map›Paper›PMID 41309528›Full record

ArticleMicrosystems & nanoengineering2025

A high-precision nanoliter droplet dispensing system based on optoelectrowetting with tunable droplet volume.

Kaicheng Huang, Zhen Liu, Yu Liu, Liming Deng, Luojia Jiang, Senlin Yan, Sijing Huang, Shuailong Zhang, Xing Cheng

Abstract read
In one paragraph

Article in Microsystems & nanoengineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Kaicheng HuangMaterials Science and Engineering, Southern University of Science and Technology, Xueyuan Avenue, Shenzhen, 518055, Guangdong, China.ORCID http://orcid.org/0000-0003-0446-9722
Zhen LiuMaterials Science and Engineering, Southern University of Science and Technology, Xueyuan Avenue, Shenzhen, 518055, Guangdong, China.
Yu LiuMaterials Science and Engineering, Southern University of Science and Technology, Xueyuan Avenue, Shenzhen, 518055, Guangdong, China.
Liming DengMaterials Science and Engineering, Southern University of Science and Technology, Xueyuan Avenue, Shenzhen, 518055, Guangdong, China.
Luojia JiangMaterials Science and Engineering, Southern University of Science and Technology, Xueyuan Avenue, Shenzhen, 518055, Guangdong, China.
Senlin YanMaterials Science and Engineering, Southern University of Science and Technology, Xueyuan Avenue, Shenzhen, 518055, Guangdong, China.
Sijing HuangMaterials Science and Engineering, Southern University of Science and Technology, Xueyuan Avenue, Shenzhen, 518055, Guangdong, China.
Shuailong ZhangSchool of Integrated Circuits and Electronics, Beijing Institute of Technology, Beijing, 100081, China.ORCID http://orcid.org/0000-0003-1004-021X
Xing ChengMaterials Science and Engineering, Southern University of Science and Technology, Xueyuan Avenue, Shenzhen, 518055, Guangdong, China. chengx@sustech.edu.cn.ORCID http://orcid.org/0000-0003-2704-1323

Funding

National Natural Science Foundation of China (National Science Foundation of China) 31927802National Natural Science Foundation of China (National Science Foundation of China) 62403231Shenzhen Science and Technology Innovation Commission RCJC20200714114436046
6 · The paper itself

Abstract

The capacity to generate high-precision droplets within Lab-on-a-Chip (LOC) devices is essential for numerous biochemical applications, such as DNA sequencing and drug delivery. In this study, we introduce an optoelectrowetting (OEW)-based droplet manipulation system that utilizes a novel droplet dispensing strategy, enabling precise nanoliter droplet dispensing with tunable droplet volume. The system comprises an OEW microchip, a liquid crystal display (LCD) projector connected to a laptop for generating customized light patterns, and a microscope equipped with a charge-coupled device (CCD) camera mounted above the OEW microchip for real-time observation. Simulations and experiments were conducted to investigate the optimal conditions for high-precision droplet dispensing. The system demonstrated exceptional stability in generating uniform droplets, with a minimum relative error (RE) of 0.45% and coefficient of variation (CV) of 2.49% for dispensing droplets of a volume of 36.52 nL. An experiment was conducted to dispense droplets of varying sizes, demonstrating the system's exceptional capability to generate droplets across a broad size range. The system was further validated through its application in polymerase chain reaction (PCR) amplification, confirming its performance in small-scale biochemical reactions. The results indicate that the proposed OEW droplet dispensing system is highly proficient in generating high-precision small-scale droplets with tunable volume. It also demonstrates its capability for biochemical processing and superior performance in sub-200 nL droplet dispensing compared to conventional pipetting techniques. This advancement holds significant potential for enhancing the performance and efficiency of LOC devices in biochemical research and clinical applications.

Identifiers

PMID41309528
PMCPMC12660984

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.