Evidence map›Paper›PMID 41318354›Full record

Observational studyJournal of human lactation : official journal of International Lactation Consultant Association2026

Human Milk Sampling Protocols: Is the Mean Macronutrient Composition of Pre- and Post-Feed Samples the Average of One Entire Feed?

Wietske Verveld, Johanna Rebecca de Wolf, Chris Giovanni Legtenberg, Nienke Bosschaart

Abstract readObservational Study
In one paragraph

Observational study in Journal of human lactation : official journal of International Lactation Consultant Association, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Wietske VerveldBiomedical Photonic Imaging Group, TechMed Centre, University of Twente, Enschede, The Netherlands.ORCID 0009-0006-3524-121X
Johanna Rebecca de WolfBiomedical Photonic Imaging Group, TechMed Centre, University of Twente, Enschede, The Netherlands.ORCID 0000-0003-4915-9648
Chris Giovanni LegtenbergBiomedical Photonic Imaging Group, TechMed Centre, University of Twente, Enschede, The Netherlands.ORCID 0009-0009-1549-3913
Nienke BosschaartBiomedical Photonic Imaging Group, TechMed Centre, University of Twente, Enschede, The Netherlands.ORCID 0000-0001-9232-1079

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHuman milk sub-sampling protocols are used in lactation research to estimate milk composition, while minimizing interference with normal breastfeeding. However, macronutrient concentrations in human milk can be highly variable, and the accuracy of sub-sampling protocols for a single breastfeed is currently unknown.

aimWe investigated the accuracy of three milk sub-sampling protocols for estimating the macronutrient concentrations of a complete feed: the mean of pre- and post-feed samples, pre-feed samples only, and post-feed samples only.

methodIn this observational study, macronutrient concentrations from each sub-sampling protocol were compared to the volume-weighted average of the complete pumping session, based on foremilk, bulk milk, and hindmilk samples from 15 mothers. Macronutrient concentrations of each milk fraction were measured with a human milk analyzer. Additionally, correlations between macronutrient concentrations and lactation characteristics were studied.

resultsMacronutrient concentrations from each sub-sampling protocol were strongly correlated with the volume-weighted average reference concentrations. Significant biases were found for the fat concentration (between -1.3 and +1.9 g/dl, depending on the protocol), but not for protein and carbohydrate concentrations.

conclusionsFor the fat concentration, none of the three sub-sampling protocols was accurate. The mean of pre- and post-feed samples could, however, be used for high-fat milk samples where measurement errors exceed the bias (+0.3 g/dl). Pre-feed or post-feed samples only should not be used to estimate the fat concentration of a complete feed. For proteins and carbohydrates, one milk sample taken at any moment in a breastfeed is sufficient to represent the concentration in the complete feed.

Indexed as

Milk, HumanNutrientsSpecimen HandlingAdultBreast FeedingFemaleHumansLactationbreastfeedingbreastfeeding assessmentfeeding patternshuman milkhuman milk collectioninfant nutritioninfrared spectroscopylactationmilk compositionobservational study

Identifiers

PMID41318354
PMCPMC13013642

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.