Evidence map›Paper›PMID 41353283›Full record

ArticleScientific reports2025

Improving the reliability of the pattern electroretinogram with adaptive filtering.

Zachary George Angus, Alexander Sarossy, Puneet Parihar, Marc Sarossy

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Zachary George AngusFaculty of Medicine, Nursing and Health Sciences, Monash University, 27 Rainforest Walk, Clayton, Melbourne, 3168, VIC, Australia. zacangus87@gmail.com.
Alexander SarossyFaculty of Medicine, Nursing and Health Sciences, Monash University, 27 Rainforest Walk, Clayton, Melbourne, 3168, VIC, Australia.
Puneet PariharFaculty of Medicine, Dentistry and Health Sciences, University of Melbourne, Melbourne, VIC, Australia.
Marc SarossyFaculty of Medicine, Nursing and Health Sciences, Monash University, 27 Rainforest Walk, Clayton, Melbourne, 3168, VIC, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electrophysiological testing of the eye and visual system is important in the diagnosis of some diseases. Unlike the electrocardiogram and other more common tests, the amplitudes of the signals are very small and subject to noise and interference. Innovative signal processing algorithms have been shown to be helpful for the electroretinogram (ERG). In this paper, we extend that work to the pattern ERG (PERG), which has utility in the assessment, diagnosis and management of central retinal and optic nerve disease. The use of the PERG has been limited by the small amplitude signal and low signal-to-noise ratio. The aim of this study was to use adaptive denoising techniques to improve the reliability and utility of the PERG. PERGs were performed on 70 eyes of 36 patients following ISCEV protocols. After a short break of approximately 2-5 min, a second recording was obtained to assess test-retest reliability of denoising. Denoising was performed on both recordings using five different adaptive filtering algorithms. Denoising algorithms generally improved test-retest reliability measured with intraclass correlation coefficient (ICC) and coefficient of repeatability (CoR). Empirical Wavelet Transform provided the best overall improvement in reliability, improving ICC from 0.79 to 0.84 (p = 0.049) and CoR from 2.12 µV to 1.69 µV (p = 0.02). Adaptive denoising algorithms may improve the reliability of PERG.

Indexed as

ElectroretinographySignal Processing, Computer-AssistedAdultAgedAlgorithmsFemaleHumansMaleMiddle AgedReproducibility of ResultsRetinaSignal-To-Noise RatioDenoisingElectroretinographyEMDEmpirical mode decompositionEWTPattern electroretinogramVMD

Identifiers

PMID41353283
PMCPMC12789682

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.