Evidence mapPaperPMID 41364855Full record

ArticleDiving and hyperbaric medicine2025

Validation and clinical use of the Maquet (Getinge) original series Rotaflow extracorporeal membrane oxygenation device in hyperbaric conditions: a technical report.

Theo Tsouras, Bridget Devaney, Zhiliang Caleb Lin, Christopher Covelli, Lloyd Roberts, Vinodh Bhagyalakshmi Nanjayya, Ian Millar

Abstract readValidation StudyCase Reports
In one paragraph

Article in Diving and hyperbaric medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Theo TsourasDepartment of Intensive Care and Hyperbaric Medicine, Alfred Health, Melbourne, Australia.
Bridget DevaneyDepartment of Intensive Care and Hyperbaric Medicine, Alfred Health, Melbourne, Australia.ORCID 0000-0001-6521-418X
Zhiliang Caleb LinDepartment of Intensive Care and Hyperbaric Medicine, Alfred Health, Melbourne, Australia.
Christopher CovelliMonash University, Melbourne, Australia.
Lloyd RobertsDepartment of Intensive Care and Hyperbaric Medicine, Alfred Health, Melbourne, Australia.
Vinodh Bhagyalakshmi NanjayyaDepartment of Intensive Care and Hyperbaric Medicine, Alfred Health, Melbourne, Australia.
Ian MillarDepartment of Intensive Care and Hyperbaric Medicine, Alfred Health, Melbourne, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Extracorporeal membrane oxygenation (ECMO) has not been previously used clinically in the modern hyperbaric chamber. We describe the modifications, validation and clinical performance of the Maquet (Getinge) original series Rotaflow (Rotaflow 1), Quadrox-i adult microporous membrane oxygenator and permanent life support (PLS) circuit under hyperbaric conditions. Methods: A Rotaflow 1 and Quadrox oxygenator underwent power supply modifications and rigorous safety testing in the hyperbaric environment using a PLS circuit primed with normal saline. Clinical validation was subsequently undertaken during a 'last resort' course of 13 hyperbaric oxygen treatment (HBOT) sessions for a patient suffering a life threatening vaso-invasive fungal infection requiring support with venovenous ECMO. Results: Preliminary testing and subsequent clinical application in the hyperbaric chamber demonstrated steady flow through the circuit based on pump revolutions per minute, with up to 180 mL (10%) variability demonstrated between the console display compared to the independent flow meter. No significant changes to flow variability were noted during pressurisation and decompression phases. Device temperature remained within safe limits. No bubbles were visually or sonographically detected. There were no performance or integrity issues detected through compression, maintenance and decompression phases. During clinical use, the patient remained stable and hyperoxygenation targets were achieved. Membrane oxygenator oxygen inflow set at up to 8 L·min-1 maintained CO2 clearance. Conclusions: After safety related modifications to the console's power supply, the Rotaflow 1 console, Quadrox oxygenator and PLS circuit performed satisfactorily up to 243 kPa during repeated clinical use.

Indexed as

Extracorporeal Membrane OxygenationHyperbaric OxygenationInvasive Fungal InfectionsOxygenators, MembraneAdultEquipment DesignHumansECMOEquipmentHyperbaric oxygen treatmentIntensive careLife supportMedical devicesPerfusion

Identifiers

PMID41364855