ArticleSensors (Basel, Switzerland)2025
Fabrication of Stretchable Piezoelectric Sensor with a Kirigami Design for Heart Sound Monitoring.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Heart sounds contain critical information about valve activity and hemodynamics, serving as an essential basis for cardiovascular disease diagnosis. However, traditional heart sound sensors are either rigid or flexible but non-stretchable, limiting their ability to accommodate chest deformation and leading to signal distortion. This study proposes an easy-to-fabricate, stretchable piezoelectric heart sound sensor with a Kirigami-inspired design, a five-layer "sandwich" structure. Periodic Kirigami cuts significantly enhance stretchability while maintaining piezoelectric conversion efficiency. Finite element simulations reveal the Kirigami structure is more sensitive to hinge length and thickness than to hinge width. Electrical tests demonstrate a linear response to sound pressure, with output voltage rising from 0.11 V to 0.42 V (70-94 dB), and voltage amplitude increasing from 9 mV to 0.35 V (60-160 Hz). The sensor exhibits excellent stability, with a maximum amplitude variation of approximately 11% under 0-30% strain, a 17% voltage decrease at 11 mm bending radius, and less than 9% output fluctuation during 1200 s continuous excitation. Seven-day monitoring confirms reliable detection of the first (S1) and second (S2) heart sounds, with signals highly consistent with ECG and a commercial sensor, verifying its potential for wearable long-term monitoring and early cardiovascular disease screening.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.