Evidence map›Paper›PMID 41405577›Full record

ArticleNMR in biomedicine2026

Venous Vessel Size Imaging Derived From A Breath-Hold Task.

Ke Zhang, Artur Hahn, Simon M F Triphan, Mark O Wielpütz, Christian H Ziener, Mark E Ladd, Heinz-Peter Schlemmer, Hans-Ulrich Kauczor, Oliver Sedlaczek, Felix T Kurz

Abstract read
In one paragraph

Article in NMR in biomedicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Ke ZhangDepartment of Diagnostic and Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany.
Artur HahnRupercht-Karls University Heidelberg, Heidelberg, Germany.
Simon M F TriphanDepartment of Diagnostic and Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany.ORCID https://orcid.org/0000-0003-2068-1184
Mark O WielpützDepartment of Diagnostic and Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany.
Christian H ZienerDivision of Radiology, German Cancer Research Center, Heidelberg, Germany.
Mark E LaddDivision of Medical Physics in Radiology, German Cancer Research Center, Heidelberg, Germany.
Heinz-Peter SchlemmerDivision of Radiology, German Cancer Research Center, Heidelberg, Germany.
Hans-Ulrich KauczorDepartment of Diagnostic and Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany.
Oliver SedlaczekDepartment of Diagnostic and Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany.
Felix T KurzDivision of Radiology, German Cancer Research Center, Heidelberg, Germany.

Funding

Bundesministerium für Bildung und Forschung (BMBF, German Federal Ministry of Education and Research) 82DZL004A1Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) 507778062
6 · The paper itself

Abstract

Vessel size imaging (VSI) to provide a measure of vessel radius in the brain has been demonstrated using an injection of contrast agent. Venous vessel radius imaging of brain microvasculature is also possible by exploiting hypercapnia and hyperoxia. However, these respiratory challenges need external devices like masks, monitors, and gas application. In this study, we employ a breath-hold task to mimic hypercapnia for venous VSI. Breath-hold experiments of brain scans were performed on 14 subjects on a 3-T scanner. Parametric maps of mean venous vessel radius were calculated from the changes in R2* and R2, ΔR2* and ΔR2, respectively, which were measured by simultaneous acquisition of gradient-echo and spin-echo signals using a spin- and gradient-echo (SAGE) echo-planar imaging sequence. In addition, we numerically simulated the expected transverse relaxation in voxels with different vessel radii based on randomly distributed cylinders to eventually obtain vessel size index q (ΔR2*/ΔR2) and associated average vessel radii. With this empirical relation of vessel size index q and vessel radius, the mean measured vessel size index was determined, and venous vessel radii in breath-hold were found to be 7.18 ± 0.49 μm in gray matter and 6.06 ± 0.22 μm in white matter. This study demonstrates the feasibility of venous VSI using a simple breath-hold task. The approach avoids contrast agents and specialized gas delivery, providing a practical alternative for assessing vascular properties. Our results show good agreement with previous hypercapnia- and contrast-based studies, supporting the validity of this noninvasive method.

Indexed as

Breath HoldingVeinsAdultBrainFemaleHumansMaleYoung AdultBOLDbreath‐hold taskvessel size imaging

Identifiers

PMID41405577
PMCPMC12710682

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.