ArticleBMC musculoskeletal disorders2025
Transformer-based and CNN-based models for clinically effective 2D and 3D pelvic bone segmentation in CT imaging.
Article in BMC musculoskeletal disorders, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Abdominal landmark detection and classification of fetal growth conditions on obstetric ultrasound: a gestational age-conditioned multi-task network.Abdominal radiology (New York) · 2026Article
- Anatomy-driven automated subsegmentation of pelvic and proximal femoral CT into clinically relevant subregions and landmarks.BMC medical imaging · 2026Article
- Deep learning and hybrid architectures for atypical and complex bone fracture diagnosis: a systematic review of performance and clinical validity.Frontiers in artificial intelligence · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveAccurate segmentation of pelvic structures and fracture fragments in trauma CT scans remains a technical challenge due to anatomical complexity and image variability. This study provides the first systematic comparison of CNN (U-Net, LinkNet) and transformer-based (UNETR) architectures in 2D and 3D formats for automated pelvic bone segmentation on the PENGWIN MICCAI 2024 challenge dataset, evaluating encoder backbones (VGG19, ResNet50) to identify optimal strategies for clinical trauma imaging. MATERIALS AND
methodsCT data from 150 patients with pelvic fractures were obtained from the PENGWIN MICCAI 2024 challenge. Preprocessing included normalization, resampling, one-hot encoding of segmentation masks, and format conversion. The segmentation task focused on classifying sacrum, left hipbone, and right hipbone, consolidating original 30-class annotations into 4 classes, providing novel benchmarks for multi-fragment pelvic fracture analysis using off-the-shelf architectures adapted to clinical trauma challenges. 2D models used a 192 × 192 resolution, and 3D models used volumetric inputs of 128 × 128 × 128 or 128 × 128 × 16. Models were trained using composite loss functions (Dice + Focal or BCE), evaluated with 5-fold cross-validation. U-Net and LinkNet were implemented with VGG19 and ResNet50 backbones; UNETR used a transformer-based encoder. Model performance was assessed via Dice coefficient, IoU, accuracy, sensitivity, and specificity. Inference speed and cross-model comparisons were conducted to analyze computational efficiency and segmentation quality.
resultsU-Net with ResNet50 achieved the highest 2D performance (Dice 0.991, IoU 0.982), while 3D U-Net with VGG19 led volumetric segmentation (Dice 0.9112). UNETR offered superior specificity (0.993) and inference consistency (< 1 min/case), albeit with lower sensitivity (0.730) in complex fragment localization. Visual analyses confirmed high anatomical fidelity. Comparison with existing literature showed our models exceeded or matched top benchmarks in Dice scores and generalizability.
conclusionsOur results confirm the efficacy of deep learning-based segmentation for pelvic fracture analysis, with high accuracy and computational efficiency supporting potential clinical integration. The models presented here demonstrate high accuracy and computational efficiency, offering a strong foundation for potential clinical integration into automated trauma imaging systems, pending external validation and workflow assessment.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.