Evidence map›Paper›PMID 41463610›Full record

ArticleBioengineering (Basel, Switzerland)2025

Device-Oriented CFD Comparison of Rectangular and Circular Microchannels with Single and Double Asymmetric Stenoses Under Identical Operating Conditions.

Mesude Avcı

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Mesude AvcıDepartment of Chemical Engineering, Cumhuriyet University, 58140 Sivas, Turkey.ORCID 0000-0001-8211-7779

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Microchannels can create disturbed flow patterns by altering pressure gradients, shear forces, and flow symmetry, which are essential in the design of microfluidic devices and, hence, blood-contacting devices. The effect of asymmetric stenosis on pressure, wall shear stress, and velocity in rectangular and circular microchannels with same operating conditions was analyzed in this study using three-dimensional (3D) steady laminar computational fluid dynamics (CFD) simulations. Asymmetric flow patterns induced by asymmetric stenosis are of particular importance and remain underexplored, especially in the context of multiple constrictions. This is, to our knowledge, is the first systematic CFD comparison of multiple asymmetric stenoses in circular microchannels directly contrasted with rectangular and single-stenosis cases under identical settings. Several parameters, such as wall shear stress (WSS), pressure, and velocity distributions, were analyzed in various stenotic and non-stenotic geometries. These microchannel models, while not reflecting real blood vessels themselves nor exhibiting wall compliance, pulsatility, or non-Newtonian rheology, replicate important mechanical characteristics of stenosis-mediated flow disturbance. Single and multiple asymmetric stenoses create flow patterns that are similar to those of vascular pathologies. For this reason, these channels should be considered as simplified device-scale models of vascular phenomena as opposed to realistic, in vitro vascular models. The results showed that asymmetric stenosis creates asymmetric velocity peaks and elevated WSS, which are more evident in the case of circular configurations with double asymmetric stenosis. The findings will help design microfluidic devices that mimic unstable flow characteristics that occur in stenotic conditions, and assist in testing clinical devices. In this study, two fabrication-ready microchannel designs under fixed operating conditions (identical inlet velocity and fluid properties) that reflect common microfluidic use were compared. Consequently, all pressure, velocity, and WSS outcomes are interpreted as device-scale responses under fixed velocity, rather than a fundamental isolation of cross-section shape, which would require matched hydraulic diameters or flow rates. This study is explicitly device-oriented, representing a fixed operating point rather than a strict geometric isolation. Accordingly, the results are also expressed with dimensionless loss coefficients (Ktot and Klocal) to enable scale-independent, device-level comparison.

Indexed as

asymmetric stenosiscomputational fluid dynamics (CFD)device-oriented comparisonhemodynamicsin vitro vascular modelsmedical device designmicrofluidic channelswall shear stress