Evidence map›Paper›PMID 41521349›Full record

ArticleJournal of robotic surgery2026

Multimodal CT-ultrasound image-guided robotic system for automated abdominal puncture.

Jinhua Li, Hao Yu, Wei Jiao, Shuxi Zhang, Sheng Tian, Jianchang Zhao, Lizhi Pan

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of robotic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jinhua LiThe key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, School of Mechanical Engineering, Tianjin University, Tianjin, 300350, China.
Hao YuThe key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, School of Mechanical Engineering, Tianjin University, Tianjin, 300350, China.
Wei JiaoThe key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, School of Mechanical Engineering, Tianjin University, Tianjin, 300350, China.
Shuxi ZhangThe key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, School of Mechanical Engineering, Tianjin University, Tianjin, 300350, China.
Sheng TianThe key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, School of Mechanical Engineering, Tianjin University, Tianjin, 300350, China.
Jianchang ZhaoThe key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, School of Mechanical Engineering, Tianjin University, Tianjin, 300350, China. zhaojianchang@tju.edu.cn.
Lizhi PanThe key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, School of Mechanical Engineering, Tianjin University, Tianjin, 300350, China. melzpan@tju.edu.cn.

Funding

the National Natural Science Foundation of China 52475027
6 · The paper itself

Abstract

Computed tomography (CT) and ultrasound provide complementary strengths for image-guided interventions, yet single-modality guidance cannot deliver high spatial resolution, soft-tissue contrast, and real-time feedback simultaneously. This study introduces a multimodal image-guided robotic system designed for precision abdominal puncture based on CT-ultrasound fusion, which aligns preoperative three-dimensional CT images with intraoperative two-dimensional ultrasound images. Optical tracking is adopted to extract CT slices that spatially correspond to the live ultrasound plane, and the spatial alignment between them is achieved via a mutual information algorithm. A compact three-degree-of-freedom puncture actuator is designed, involving entry-point positioning, orientation adjustment, and needle advancement. The actuator rigidly integrates a probe clamping mechanism to preserve image-actuator co-registration. Phantom validation proved anatomically consistent fused displays and reliable guidance of the proposed system, and the puncture trials targeting renal calyces yielded a mean positional error of 1.17 mm and a mean angular error of 0.43°. The compact puncture actuator reduces footprint in the operating room and simplifies the calibration and clinical workflow. The proposed design provides a practical route toward safer and more reproducible minimally invasive abdominal interventions.

Indexed as

AbdomenMultimodal ImagingPuncturesRobotic Surgical ProceduresSurgery, Computer-AssistedTomography, X-Ray ComputedAlgorithmsHumansImaging, Three-DimensionalPhantoms, ImagingUltrasonographyCT-ultrasound fusionImage-guided robotic puncturePercutaneous abdominal interventionPercutaneous surgical robot

Identifiers

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.