Evidence map›Paper›PMID 41532128›Full record

ArticleBiomedical optics express2026

Translational photoacoustic and ultrasound imaging catheter for characterizing gastrointestinal inflammation and fibrosis: a study with a pig model

Yaocai Huang, Laura A Johnson, Xiaorui Peng, Yao Lee, Xueding Wang, Peter D R Higgins, Guan Xu

Abstract read
In one paragraph

Article in Biomedical optics express, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yaocai HuangDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA.ORCID https://orcid.org/0009-0002-8597-4834
Laura A JohnsonDepartment of Internal Medicine, University of Michigan, Ann Arbor, MI 48109, USA.
Xiaorui PengDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA.ORCID https://orcid.org/0000-0001-5756-7591
Yao LeeLaboratory Animal Medicine Unit, University of Michigan, Ann Arbor, MI 48109, USA.
Xueding WangDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA.
Peter D R HigginsDepartment of Internal Medicine, University of Michigan, Ann Arbor, MI 48109, USA.
Guan XuDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA.

Funding

Measuring Molecular and Mechanical Outcomes of Endoscopic Dilation of Fibrotic StricturesR01DK125687 · NIDDK · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI Peter D.R. Higgins, Guan Xu · 2020 to 2026
$3.3M
Real time fine needle assessment of architectural heterogeneity in prostate cancerR37CA222829 · NCI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI XU, GUAN · 2019 to 2025
$3.2M
NCI NIH HHS R37 CA222829NIDDK NIH HHS R01 DK125687
6 · The paper itself

Abstract

Our previous studies demonstrated that a prototype photoacoustic (PA) and ultrasound (US) imaging catheter can differentiate intestinal inflammation and fibrosis. However, its compatibility with clinical endoscopic procedures has not been validated. Here, we present a translational PA-US dual-modality imaging catheter with a reduced diameter to fit the biopsy channel of standard adult colonoscopes and therapeutic upper endoscopes (∼3.7 mm). The catheter integrates an angle-tipped optical fiber (600-µm core) for PA illumination and a miniaturized 48-element ultrasound array operating at a center frequency of ∼9 MHz for signal reception. These components are enclosed in a hydrostatic balloon (12 mm diameter, 15 mm length when fully inflated) to ensure acoustic coupling with the intestinal lumen. The system was upgraded from our previous setup by incorporating a more portable optical parametric oscillator (OPO) laser and a Verasonics imaging platform. The imaging catheter was positioned at the disease locations in a pig model of esophageal fibrosis induced by argon plasma coagulation (APC). Multi-wavelength PA imaging and US imaging were performed to resolve the tissue components. The results demonstrate the catheter's ability to assess inflammation and fibrosis in the gastrointestinal tract during a standard clinical endoscopy procedure.

Identifiers

PMID41532128
PMCPMC12795418

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.