Evidence map›Paper›PMID 41552726›Full record

ArticleRSC advances2026

Fluorescent biosensor based cerium-doped carbon quantum dots for albumin detection.

Nashwa Ashraf Hafez, Eman Fadl, Shaker Ebrahim, Moataz Soliman, Azza Shokry

Abstract read
In one paragraph

Article in RSC advances, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Nashwa Ashraf HafezDepartment of Materials Science, Institute of Graduate Studies and Research, Alexandria University P.O. Box 832 Alexandria Egypt azzashokry@alexu.edu.eg.
Eman FadlDepartment of Materials Science, Institute of Graduate Studies and Research, Alexandria University P.O. Box 832 Alexandria Egypt azzashokry@alexu.edu.eg.
Shaker EbrahimDepartment of Materials Science, Institute of Graduate Studies and Research, Alexandria University P.O. Box 832 Alexandria Egypt azzashokry@alexu.edu.eg.
Moataz SolimanDepartment of Materials Science, Institute of Graduate Studies and Research, Alexandria University P.O. Box 832 Alexandria Egypt azzashokry@alexu.edu.eg.
Azza ShokryDepartment of Materials Science, Institute of Graduate Studies and Research, Alexandria University P.O. Box 832 Alexandria Egypt azzashokry@alexu.edu.eg.ORCID https://orcid.org/0000-0001-6625-2874

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Accurate detection of albumin proteins is crucial for diagnosing different diseases. A fluorescent sensor has been developed using cerium (Ce) doped carbon quantum dots (CQDs) to detect bovine serum albumin (BSA) in blood and urine samples. Pristine CQDs and Ce-CQDs were synthesized through citric acid pyrolysis. CQDs and Ce-CQDs exhibited emission peaks at 415 nm and 426 nm, respectively. Based on the photoluminescence (PL) enhancement of Ce-CQDs resulting from adding BSA, BSA was quantified within two minutes. This biosensor was selective and sensitive towards BSA in the concentrations ranging from 1 to 1000 µM with a high correlation coefficient and a low detection limit of 0.98 µM (6.5 × 10

Identifiers

PMID41552726
PMCPMC12810693

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked