Evidence map›Paper›PMID 41576240›Full record

ArticleLab on a chip2026

Online affinity micro free-flow electrophoresis for the continuous monitoring of insulin

Gretchen S Burke, Seokwon Jo, Emilyn U Alejandro, Michael T Bowser

Abstract read
In one paragraph

Article in Lab on a chip, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Gretchen S BurkeDepartment of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, USA. bowser@umn.edu.ORCID 0009-0004-9474-7259
Seokwon JoDepartment of Integrative Biology and Physiology, University of Minnesota Medical School, University of Minnesota, 2231 6th Street SE, Minneapolis, MN 55455, USA.
Emilyn U AlejandroDepartment of Integrative Biology and Physiology, University of Minnesota Medical School, University of Minnesota, 2231 6th Street SE, Minneapolis, MN 55455, USA.ORCID 0000-0002-7941-8439
Michael T BowserDepartment of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, USA. bowser@umn.edu.ORCID 0000-0002-1570-2414

Funding

Online Affinity Micro Free Flow Electrophoresis Assays for Continuous Monitoring of Biochemical MessengersR01GM145956 · NIGMS · UNIVERSITY OF MINNESOTA · PI BOWSER, MICHAEL T · 2022 to 2025
$1.2M
NIGMS NIH HHS R01 GM145956
6 · The paper itself

Abstract

An online, micro free-flow electrophoresis (μFFE) assay was developed for the real-time measurement of insulin in a continuous, competitive immunoassay. Fluorescently labeled insulin and anti-insulin monoclonal antibody were mixed with the sample stream online and flowed through an incubation capillary into the μFFE device. Under an electric field, the bound antibody : insulin-FITC complex was separated from free insulin-FITC. When unlabeled insulin was introduced, labeled and unlabeled insulin competed for binding sites on the antibody, and the separated peaks of the bound complex and free insulin-FITC responded in real-time. Temporal resolution of 30 seconds was achieved following injections of unlabeled insulin, with a limit of detection of 63 nM and a linear response over the tested range of 50 nM to 1 μM insulin. The development of this assay supports the eventual integration of an organ-on-a-chip system capable of measuring direct cellular efflux in tandem with the affinity μFFE detection system. To approximate such an online cellular response, glucose-stimulated insulin secretion was collected offline from human islets and injected into the affinity μFFE instrument. A measurable change in insulin secretion was observed between samples exposed to low and high glucose, demonstrating sufficient limit of detection, linearity, the compatibility of the instrument with a complex biological matrix.

Indexed as

ElectrophoresisInsulinAntibodies, MonoclonalHumansImmunoassayIslets of LangerhansLimit of DetectionAntibodies, MonoclonalInsulin

Identifiers

PMID41576240
PMCPMC12974320

What Socratic holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.