Preliminary development and validation of a textile-based pressure-sensing system for lower-limb prosthetic sockets.
Article in Biomedical engineering online, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
backgroundThe socket is an essential component of prostheses and critical to the mobility, quality of life, and independence of individuals with lower-limb loss. A poor-fitting socket can lead to residual limb health issues, gait abnormalities, and prosthesis abandonment. To mitigate these risks, prosthetists routinely evaluate socket fit, but current assessments rely largely on subjective measures, which may not consistently ensure optimal outcomes. The use of pressure sensors at the limb-socket interface could enhance these evaluations, yet challenges with practicality and wearability have limited their clinical adoption. To address these gaps, we developed and evaluated a prosthetic sock with integrated textile-based pressure-sensing cells.
resultsIndividual cells were first loaded to evaluate sensitivity, repeatability, and drift. Then, a surrogate residual limb was fabricated from silicone and 3D-printed components to assess performance at the limb-socket interface. The sensitivity test demonstrated the ability to detect load changes equivalent to 5% of the maximum load throughout the full range, while the repeatability evaluation resulted in an intraclass correlation coefficient of 0.998 (0.996-1.000) and a percentage coefficient of variation (CV) below 2%. The average drift over 10 min was 3.03 ± 0.44%. When loading the residual limb in the neutral standing position, three out of four sock cells tested at the limb-socket interface showed percentage CVs below 10%. Finally, all cells tested detected changes in socket pressure distribution under simulated gait events when applying a load of 600 N.
conclusionsThese results were similar to commonly used off-the-shelf pressure sensors, and the sock performance is, therefore, promising. However, further development is required, including form factor improvements, implementation of shear-sensing capabilities, calibration, and validation with prosthesis users.