ArticleFrontiers in sports and active living2025
Intra-tester and inter-tester reliability of maximum isokinetic hip and knee strength measurements with the exoskeleton in healthy young adults.
Article in Frontiers in sports and active living, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: The UGO exoskeleton enables gait training and simultaneous, Methods: Two independent cohorts were enrolled to determine the inter- and intra-tester reliability of the UGO exoskeleton. Each cohort consisted of 20 fourth-year undergraduate students (10 male, 10 female), with mean ages of 22.55 ± 1.05 and 21.40 ± 1.00 years, respectively. Testing was conducted by two experienced therapists. Peak isokinetic torque (Nm) in hip and knee flexors and extensors was collected. Relative and absolute reliability of peak torques were estimated using the intra-class correlation coefficient (ICC) and standard error of measurement (SEM), respectively. Bland-Altman plot was utilized to further elucidate the differences between tests obtained by different testers or by the same tester at different times. Results: Inter-tester reliability was good-to-excellent, as evidenced by ICCs of 0.791-0.906 for the hip and 0.859-0.975 for the knee (all Conclusions: The UGO exoskeleton provides a reliable, time-efficient, and functionally relevant means of quantifying hip- and knee-flexor and -extensor torque in healthy young adults while maintaining a posture that closely replicates natural gait.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.