Evidence map›Paper›PMID 41589400›Full record

ArticleMedical physics2026

Image reconstruction and elongation artifact reduction for a dual-panel dedicated prostate PET scanner.

Abdollah Saberi Manesh, Mehdi Amini, Yazdan Salimi, Katayoun Doroud, Crispin Williams, Themistoklis Williams, Hossein Arabi, Habib Zaidi

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Abdollah Saberi ManeshDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland.ORCID https://orcid.org/0000-0001-7327-2558
Mehdi AminiDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland.ORCID https://orcid.org/0000-0002-4370-680X
Yazdan SalimiDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland.ORCID https://orcid.org/0000-0002-1233-9576
Katayoun DoroudPicotech, St Genis Pouilly, France.
Crispin WilliamsPicotech, St Genis Pouilly, France.
Themistoklis WilliamsPicotech, St Genis Pouilly, France.
Hossein ArabiDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland.ORCID https://orcid.org/0000-0001-6526-0960
Habib ZaidiDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland.ORCID https://orcid.org/0000-0001-7559-5297

Funding

Eurostars program of the European Commission E! 114021Private Foundation of Geneva University Hospitals RC-06-01
6 · The paper itself

Abstract

backgroundThe development of PET scanners dedicated to high temporal and spatial resolution organ-specific imaging is an active research area, motivated by the need for cost reduction, improved lesion detectability and quantification in specific clinical scenarios, as well as by ongoing hardware and software innovations. PURPOSE: This study investigates and compares various image reconstruction strategies for a dual-panel prostate-dedicated PET scanner (ProVision), which features four-layered dual-readout time-of-flight depth-of-interaction detectors and a 22-position acquisition protocol to improve angular coverage. MATERIALS AND

methodsA list-mode MLEM algorithm with multi-ray modeling was developed and optimized using a scaled NEMA image quality phantom to determine optimal number of rays and iterations. These parameters were then used to reconstruct data from both simulation and experimental acquisitions, including an anthropomorphic pelvis phantom, named Adam-PETer. Four reconstruction approaches were evaluated: classical MLEM; MLEM with embedded shift-variant point spread function (PSF) modeling; a hybrid list-mode reconstruction; and a Swin-UNETR-based deep learning model applied as a post-reconstruction enhancement to MLEM images. Performance was assessed using contrast recovery coefficient (CRC), contrast-to-noise ratio (CNR), and contrast-to-noise consistency (CNC), on both a scaled NEMA phantom and an experimental anthropomorphic phantom.

resultsIn the scaled NEMA phantom simulation, the Swin-based method yielded the highest CNR and CNC, especially for the smallest spheres, thereby outperforming both standard MLEM and the hybrid algorithm. In the Adam-PETer experimental prostate phantom, the CNR was 10.43 for MLEM, 14.48 for Hybrid, and 13.85 for Swin for the larger lesion (10 mm). The CNR values were 2.28, 3.03, and 4.35, respectively, for the smaller lesion (8 mm). CNC values also varied across methods, with Swin achieving the best result for the smaller lesion. These findings indicate that model-based and learned methods offer complementary strengths depending on lesion contrast and size.

conclusionThe PET scanner-adapted reconstruction combined with deep learning refinement improves image quality in dedicated, limited-angle PET systems.

Indexed as

ArtifactsImage Processing, Computer-AssistedPositron-Emission TomographyProstateAlgorithmsHumansMalePhantoms, Imagingartifactdeep‐learningdual‐panelorgan‐specific PETprostatereconstruction

Identifiers

PMID41589400
PMCPMC12836138

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.