Evidence map›Paper›PMID 41600530›Full record

ArticleSensors (Basel, Switzerland)2026

CHARMS: A CNN-Transformer Hybrid with Attention Regularization for MRI Super-Resolution.

Xia Li, Haicheng Sun, Tie-Qiang Li

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Xia LiCollege of Information Engineering, China Jiliang University, Hangzhou 314423, China.ORCID 0000-0002-9429-1050
Haicheng SunCollege of Information Engineering, China Jiliang University, Hangzhou 314423, China.
Tie-Qiang LiSchool of Medical Imaging, Fujian Medical University, Fuzhou 350005, China.ORCID 0000-0002-4866-5904

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Magnetic resonance imaging (MRI) super-resolution (SR) enables high-resolution reconstruction from low-resolution acquisitions, reducing scan time and easing hardware demands. However, most deep learning-based SR models are large and computationally heavy, limiting deployment in clinical workstations, real-time pipelines, and resource-restricted platforms such as low-field and portable MRI. We introduce CHARMS, a lightweight convolutional-Transformer hybrid with attention regularization optimized for MRI SR. CHARMS employs a Reverse Residual Attention Fusion backbone for hierarchical local feature extraction, Pixel-Channel and Enhanced Spatial Attention for fine-grained feature calibration, and a Multi-Depthwise Dilated Transformer Attention block for efficient long-range dependency modeling. Novel attention regularization suppresses redundant activations, stabilizes training, and enhances generalization across contrasts and field strengths. Across IXI, Human Connectome Project Young Adult, and paired 3T/7T datasets, CHARMS (~1.9M parameters; ~30 GFLOPs for 256 × 256) surpasses leading lightweight and hybrid baselines (EDSR, PAN, W2AMSN-S, and FMEN) by 0.1-0.6 dB PSNR and up to 1% SSIM at ×2/×4 upscaling, while reducing inference time ~40%. Cross-field fine-tuning yields 7T-like reconstructions from 3T inputs with ~6 dB PSNR and 0.12 SSIM gains over native 3T. With near-real-time performance (~11 ms/slice, ~1.6-1.9 s per 3D volume on RTX 4090), CHARMS offers a compelling fidelity-efficiency balance for clinical workflows, accelerated protocols, and portable MRI.

Indexed as

Image Processing, Computer-AssistedMagnetic Resonance ImagingAlgorithmsBrainConnectomeConvolutional Neural NetworksDeep LearningHumansattention regularizationclinical deploymentCNN-Transformer hybridlightweight networkMRI super-resolutionreverse residual attention

Identifiers

PMID41600530
PMCPMC12845672

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.