Evidence map›Paper›PMID 41632092›Full record

ArticleInvestigative radiology2026

A Practical Rule-of-Thumb to Adapt Contrast Media Dose in Photon-counting Detector CT: The 10-to-5 Rule.

Cécile R L P N Jeukens, Bibi Martens, Janneke Vandewall, Sören Jasper, Guy Schrijnemaekers, Joachim E Wildberger, Thomas G Flohr

Abstract read
In one paragraph

Article in Investigative radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Cécile R L P N Jeukens
Bibi Martens
Janneke Vandewall
Sören Jasper
Guy Schrijnemaekers
Joachim E Wildberger
Thomas G Flohr

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo develop a simple rule-of-thumb on how to reduce the contrast medium (CM) dose in photon-counting detector CT (PCD-CT) when lowering the energy of the reconstructed virtual mono-energetic images (VMI) while maintaining the contrast-to-noise ratio (CNR) for parenchymal CT and CTA. MATERIALS AND

methodsSpectral abdominal and chest CT phantoms were scanned using a portal venous phase (PVP) abdominal and a high-pitch CTA protocol, respectively, on a first-generation dual-source PCD-CT. The phantoms contained cylindrical rods with iodine in water equivalent material (0.5/1.0/2.0/5.0/10.0/15.0 mg I/mL) and ICRU muscle tissue. The phantoms were complemented with 2 fat equivalent rings to mimic different patient sizes. Iodine contrast, image noise, noise power spectra (NPS), and iodine CNR were investigated in VMIs with different energies (40 to 60 keV in steps of 5 keV). This was done for different iodine concentrations, phantom sizes, x-ray tube voltages (120 kV and 140 kV) and radiation doses. In addition, 15 abdominal and 15 CT angiographic patient scans [body mass index (BMI) range: 17 to 37 kg/m 2 ] were retrospectively analyzed to determine the CNR at different VMI energies.

resultsContrast at a given iodine concentration and VMI energy was independent of phantom size, radiation dose, and acquisition voltage (kV). With decreasing VMI energy, the maximum of the NPS curves increased, while their shape remained similar, indicating higher noise but similar noise texture. The CNR increased with lower VMI energy for a given iodine concentration and phantom size, while CNR decreased with increasing phantom size for a given VMI energy and iodine concentration. When the VMI energy was lowered by 5 keV steps in the range of 60 to 40 keV, similar CNR could be maintained when reducing the iodine concentration at each step by 11.7% to 13.7% for abdominal PVP scans and 11.8% to 14.5% for CTAs. CNR analysis of the patient scans confirmed these findings: a 5 keV reduction in VMI energy led to a mean±SD 11.4%±0.4% and 13.7%±1.0% increase in CNR for abdomen PVP and CTA scans, respectively. This can be translated to a corresponding reduction in CM dose when a constant CNR is aimed for. From these results, a simple, robust rule-of-thumb was derived, the 10-to-5 rule: For the evaluated PCD-CT protocols, CNR can be maintained with about 10% less CM dose for each reduction of the VMI energy by 5 keV.

conclusionsThis phantom study, which was complemented with a retrospective proof-of-principle patient study, showed that a simple, easy to implement 10-to-5 rule-of-thumb might be used in daily practice for contrast-enhanced PCD-CT. It allows for individual adaptation of the CM dose to the VMI energy applied.

Indexed as

Contrast MediaRadiation DosageTomography, X-Ray ComputedHumansPhantoms, ImagingPhotonsRadiography, AbdominalReproducibility of ResultsSignal-To-Noise RatioContrast Mediaabdomen PVPcomputed tomographycontrast mediaCTAdiagnostic imaginginjection protocolphoton-counting CT

Identifiers

PMID41632092
PMCPMC13317918

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.