Clinical feasibility test of 60 kVp double-low-dose coronary CT angiography with a deep learning reconstruction algorithm.

Xi Wu, Manman Zhu, Yixuan Zou, Jialin Luo, Weiling He, Wenjie Sun, Hui Shi, Peng Liu, Feng Huang

Abstract read
In one paragraph

Article in Insights into imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Xi WuDepartment of Radiology, Hunan Provincial People's Hospital (The First Affiliated Hospital of Hunan Normal University), Changsha, China.
Manman ZhuUnited Imaging Healthcare, Shanghai, China.
Yixuan ZouUnited Imaging Healthcare, Shanghai, China.
Jialin LuoDepartment of Radiology, Hunan Provincial People's Hospital (The First Affiliated Hospital of Hunan Normal University), Changsha, China.
Weiling HeDepartment of Radiology, Hunan Provincial People's Hospital (The First Affiliated Hospital of Hunan Normal University), Changsha, China.
Wenjie SunDepartment of Radiology, Hunan Provincial People's Hospital (The First Affiliated Hospital of Hunan Normal University), Changsha, China.
Hui ShiDepartment of Radiology, Hunan Provincial People's Hospital (The First Affiliated Hospital of Hunan Normal University), Changsha, China.
Peng LiuDepartment of Radiology, Hunan Provincial People's Hospital (The First Affiliated Hospital of Hunan Normal University), Changsha, China.
Feng HuangDepartment of Radiology, Hunan Provincial People's Hospital (The First Affiliated Hospital of Hunan Normal University), Changsha, China. huangfeng0722@163.com.ORCID http://orcid.org/0000-0003-1737-4757

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo test the feasibility of 60 kVp double-low-dose coronary CT angiography (CCTA) with a deep learning reconstruction (DLR) algorithm. MATERIALS AND

methodsEighty-nine patients (44 females, 59.9 ± 13.2 years, 23.1 ± 3.3 kg/m

resultsDouble-low-dose CCTA achieved a significant reduction in both radiation dose (0.60 ± 0.12 mSv vs 4.43 ± 1.42 mSv) and contrast volume compared to routine-dose CCTA. For the per-segment level, LD-DLR showed significantly higher specificity (0.99 vs 0.94), positive predictive value (0.91 vs 0.68), and accuracy (0.98 vs 0.94) for ≥ 50% coronary stenosis compared to LD-HIR. The area under the curve of LD-DLR was significantly higher than LD-HIR for ≥ 50% stenosis at per-segment (0.94 vs 0.92), per-vessel (0.92 vs 0.89), and per-patient (0.92 vs 0.85) levels; and for CT-FFR ≤ 0.80 at per-vessel (0.94 vs 0.74), LAD-vessel (0.94 vs 0.71), and LCX-vessel (0.99 vs 0.67) levels. The IQS, SNR, and CNR of LD-DLR were not inferior to those of RD-HIR in all segments.

conclusionsThe 60 kVp double-low-dose CCTA with DLR can significantly reduce radiation dose and simultaneously maintain the high consistency of coronary stenosis and CT-FFR assessments with routine-dose CCTA. CRITICAL RELEVANCE STATEMENT: The 60 kVp double-low-dose CCTA protocol is feasible with a novel DLR algorithm without compromising the performance of coronary stenosis and CT-FFR assessments. KEY POINTS: Is a 60 kVp double-low-dose CCTA protocol with a DLR algorithm feasible for routine clinical application? The 60 kVp CCTA protocol with the DLR algorithm reduced radiation dose by 86.5% and contrast dose by 36.4%. The 60 kVp CCTA with DLR achieved high consistency of coronary stenosis and CT-FFR values with the routine-dose 100 kVp CCTA.

Indexed as

Coronary CT angiographydeep learning reconstructionlow-dose

Identifiers

PMID41665766
PMCPMC12891270