Evidence map›Paper›PMID 41688946›Full record

ArticleBMC musculoskeletal disorders2026

Optimizing plate working length and screw configuration for femoral shaft plate fixation: a finite element analysis under different bone quality scenarios.

Shou-I Chen, Wei-Sheng Hong, Tzu-Hao Tseng, Shau-Huai Fu

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Shou-I ChenDepartment of Mechanical Design Engineering, National Formosa University, Huwei Township, Yunlin County, Taiwan.
Wei-Sheng HongDepartment of Mechanical Design Engineering, National Formosa University, Huwei Township, Yunlin County, Taiwan.
Tzu-Hao TsengDepartment of Orthopaedic Surgery, National Taiwan University Hospital, No.7, Chung Shan S. Rd. (Zhongshan S. Rd.), Zhongzheng Dist., Taipei City, 100225, Taiwan. b92401004@gmail.com.
Shau-Huai FuDepartment of Orthopaedic Surgery, National Taiwan University Hospital, No.7, Chung Shan S. Rd. (Zhongshan S. Rd.), Zhongzheng Dist., Taipei City, 100225, Taiwan. b90401045@gmail.com.

Funding

National Science and Technology Council NSTC 113-2221-E-150-001National Taiwan University Hospital, Yunlin branch NTUHYL 114.C002
6 · The paper itself

Abstract

backgroundLateral locking plate fixation serves as an alternative to intramedullary nailing for femoral shaft fractures in patients with narrow medullary canals or existing implants. However, the optimal screw configuration—particularly working length and screw positioning—remains uncertain, especially in comminuted fractures where construct stiffness and interfragmentary strain are critical for healing.

methodsFinite element femur models were developed based on Sawbones model. A total of 27 models were constructed by combining three bone quality conditions (high, medium, and low) with nine clinically relevant screw configurations. The effects of working length and screw positioning on interfragmentary strain and plate stress were evaluated under an 800 N axial load simulating single-leg stance.

resultsLonger working lengths resulted in increased interfragmentary strain and plate stress. Configurations with the second screw positioned farther from the fracture site also showed elevated stress and strain. Among all models, configuration 8S_C4 (intermediate working length) demonstrated the most favorable biomechanical profile, achieving strain levels near the 5% threshold for secondary healing while maintaining relatively low plate stress. These findings were consistent across all bone quality conditions.

conclusionThis study provides biomechanical evidence that both working length and screw positioning significantly influence construct behavior in lateral locking plate fixation of comminuted femoral shaft fractures. The 8S_C4 configuration is recommended for its optimal balance of promoting favorable strain for healing and minimizing plate stress. These insights may inform screw placement strategies to improve clinical outcomes.

trial registrationNot applicable, this is a finite element study.

Indexed as

Bone PlatesBone ScrewsFemoral FracturesFemurFinite Element AnalysisFracture Fixation, InternalBiomechanical PhenomenaBone DensityHumansStress, MechanicalFemoral fractureFinite element analysisStrainStressWorking length

Identifiers

PMID41688946
PMCPMC13011666

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.