ArticlePloS one2026
A hybrid CNN-spectral architecture for non-contact respiratory rate estimation using multi-region optical-flow analysis.
Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Respiratory rate (RR) is a key indicator for assessing health conditions, yet noncontact measurement remains challenging due to motion artifacts, lighting variability, and skin-tone differences. This study presents a robust framework combining a custom convolutional neural network (CNN) with spectral analysis of optical-flow signals to estimate RR accurately across diverse population. Respiration-induced motion is extracted from six anatomical regions: forehead, cheeks, upper chest, and shoulders. Adaptive Kalman filtering combined with signal-to-noise ratio (SNR)-based weighted fusion enables reliable RR estimation. To improve generalizability, extensive data augmentation was applied, simulating illumination conditions ranging from normal to low light. The experimental results indicate that the proposed method achieves a mean average error (MAE) of 0.61-0.95 breaths per minute (bpm) for different skin tones and ages, within the clinically relevant range. These findings support the effectiveness of the multi-region CNN-spectral framework as a reliable, noncontact, real-time respiratory monitoring solution with potential for continuous healthcare and telemedicine applications.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.