Evidence map›Paper›PMID 41743403›Full record

ArticleIEEE transactions on radiation and plasma medical sciences2025

DG-DiT: Dual-Branch Gating Diffusion Transformer for Multi-Tracer and Multi-Scanner Brain PET Image Denoising.

Ziyuan Zhou, Fan Yang, Tzu-An Song, Bowen Lei, Yubo Zhang, Joyita Dutta

Abstract read
In one paragraph

Article in IEEE transactions on radiation and plasma medical sciences, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ziyuan ZhouDepartment of Biomedical Engineering at the University of Massachusetts Amherst, Amherst, MA 01003, USA.
Fan YangDepartment of Biomedical Engineering at the University of Massachusetts Amherst, Amherst, MA 01003, USA.
Tzu-An SongDepartment of Biomedical Engineering at the University of Massachusetts Amherst, Amherst, MA 01003, USA.
Bowen LeiDepartment of Biomedical Engineering at the University of Massachusetts Amherst, Amherst, MA 01003, USA.
Yubo ZhangDepartment of Biomedical Engineering at the University of Massachusetts Amherst, Amherst, MA 01003, USA.
Joyita DuttaDepartment of Biomedical Engineering at the University of Massachusetts Amherst, Amherst, MA 01003, USA.

Funding

Longitudinal predictive modeling for tau in Alzheimer's diseaseR01AG072669 · NIA · MASSACHUSETTS GENERAL HOSPITAL · PI DUTTA, JOYITA · 2021 to 2025
$2.7M
Super-Resolved Multimodal Imaging Biomarkers for Frontotemporal DementiaR21AG087392 · NIA · UNIVERSITY OF MASSACHUSETTS AMHERST · PI DUTTA, JOYITA, SARANATHAN, MANOJKUMAR · 2024 to 2025
$474k
Super-Resolution Tau PET Imaging for Alzheimer's DiseaseR03AG070750 · NIA · UNIVERSITY OF MASSACHUSETTS LOWELL · PI DUTTA, JOYITA · 2021 to 2022
$304k
Early Alzheimers Forecasting from Multimodal Data via Deep Transfer Learning, Evaluated on a Large-Scale Prospective Cohort StudyR03AG083708 · NIA · UNIVERSITY OF MASSACHUSETTS AMHERST · PI DUTTA, JOYITA, FITERAU BROSTEAN, MADALINA · 2023 to 2023
$287k
NIA NIH HHS R01 AG072669NIA NIH HHS R03 AG070750NIA NIH HHS R03 AG083708NIA NIH HHS R21 AG087392
6 · The paper itself

Abstract

Diffusion probabilistic models (DPMs) have been demonstrated to be effective for denoising positron emission tomography (PET) images due to their ability to model complex data distributions. However, limitations in efficiency, accuracy, and generalizability remain open challenges in this area. In PET denoising, where high fidelity to the ground truth is critical, DPMs often require a large number of iterations and tend to offer limited quantitative accuracy. Moreover, traditional DPMs struggle to model variabilities in the data distribution arising from the use of multiple scanners and tracers. To address these issues, we propose a dual-branch gating diffusion transformer (DG-DiT) network for multi-tracer and multi-scanner PET denoising. The proposed DG-DiT exploits the strong distribution modeling capabilities of a diffusion transformer (DiT) to learn prior knowledge from a compact and regularized latent space. The design of the latent space enables efficient few-step diffusion. In addition, an image restoration transformer (IRT) model is employed for generating the final denoised image. The DiT backbone and the IRT both utilize a dual-branch gating mechanism to efficiently fuse information from multiple inputs. We conducted extensive experiments on multi-tracer and multi-scanner datasets. The results demonstrate that the proposed DG-DiT model achieves the highest quantitative accuracy across every scanner and tracer, with a PSNR improvement of up to 0.2 dB compared to several state-of-the-art deep learning models. Contrast-to-noise ratio evaluation shows that the proposed model is able to recover contrast in small and critical brain regions while effectively reducing noise. This suggests that the proposed DG-DiT model can consistently deliver superior denoising performance.

Indexed as

artificial intelligencedenoisingdiffusion modeldiffusion transformerPositron emission tomography

Identifiers

PMID41743403
PMCPMC12931958

What Socratic holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.