Evidence mapPaperPMID 41744697Full record

ArticleBiosensors2026

Development of a Non-Contact Flow Sensor Based on a Permanent Magnet Metal Clip for Monitoring Circulation Status.

Kicheol Yoon, Seung Hee Choi, Tae-Hyeon Lee, Sangyun Lee, Sunghoon Kang, Sun Jin Sym, Kwang Gi Kim

Abstract read
In one paragraph

Article in Biosensors, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Kicheol YoonGachon Biomedical Convergence Institute, Gachon University Gil Medical Center, Incheon 21565, Republic of Korea.
Seung Hee ChoiDepartment of Electronic Engineering, Gyeonggi University of Science and Technology, 269 Gyeonggigwagi-dearo, Siheung City 15073, Gyeonggi-do, Republic of Korea.
Tae-Hyeon LeeDepartment of Electronic Engineering, Gyeonggi University of Science and Technology, 269 Gyeonggigwagi-dearo, Siheung City 15073, Gyeonggi-do, Republic of Korea.
Sangyun LeeDepartment of Radiological Science, Dongnam Health University, 50 Cheoncheon-ro 74 gil, Jangan-gu, Suwon 16328, Gyeonggi-do, Republic of Korea.
Sunghoon KangMedical Devices R&D Center, Gachon University Gil Medical Center, 21, 774 beon-gil, Namdong-daero, Namdong-gu, Incheon 21565, Republic of Korea.
Sun Jin SymDivision of Medical Oncology, Department of Internal Medicine, Gachon University Gil Medical Center, 21, 774 beon-gil, Namdong-daero, Namdong-gu, Incheon 21565, Republic of Korea.ORCID 0000-0002-1340-6291
Kwang Gi KimMedical Devices R&D Center, Gachon University Gil Medical Center, 21, 774 beon-gil, Namdong-daero, Namdong-gu, Incheon 21565, Republic of Korea.ORCID 0000-0001-9714-6038

Funding

Korea Health Industry Development Institute RS-2024-00405083
6 · The paper itself

Abstract

Foreign matter accumulating on catheters during ascites paracentesis in cancer patients can interfere with the procedure. The paracentesis site must be visually inspected by patients or medical staff. We propose a monitoring method using sensors, as they enable real-time, automatic status detection. The proposed design integrates a sensor into the drainage tube to detect liquid flow using the Lorentz force. The sensor consists of a permanent magnet, a yoke, and a signal processing circuit. Mu-metal shields the magnet to prevent interference with surrounding circuits. Physiological saline solution is used as a substitute for bodily fluids. Sensor performance was evaluated via finite element analysis. The Lorentz force generated an average voltage of 11.07 μV when liquid was present, enabling detection of the flow status. The proposed sensor is non-invasive and features a clip design, allowing attachment and detachment from the drainage tube for reuse. Non-invasiveness ensures safety from infection, and reusability can reduce medical costs. This study proposes a sensor for monitoring peritoneal puncture status. By detecting liquid flow using the Lorentz force, the system enables real-time monitoring during the procedure.

Indexed as

Lorentz forcemultiple puncturesmu-metalnon-contact flow sensorpermanent magnet

Identifiers

PMID41744697
PMCPMC12937992

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked