Evidence map›Paper›PMID 41753804›Full record

ArticleMicromachines2026

A Responsive and Precise Particle Position Control System Combining a Sidewall-Driven Peristaltic Micropump and a High-Speed Camera.

Yuta Tanaka, Toshio Takayama

Abstract read
In one paragraph

Article in Micromachines, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Yuta TanakaDepartment of Mechanical Engineering, Institute of Science Tokyo, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8552, Japan.
Toshio TakayamaDepartment of Mechanical Engineering, Institute of Science Tokyo, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8552, Japan.ORCID 0000-0002-0411-4764

Funding

JSPS KAKENHI 21H03837
6 · The paper itself

Abstract

The systems to manipulate a single particle in a microfluidic channel can be adopted to pharmacological and cytological experiments of single-cell observation. The common cell position systems use syringe pumps driven by piezoelectric devices, and these have a flow quantity limit. To achieve single-cell manipulation using actuators without limiting the flow quantity and with a low risk of contamination, we propose a particle control system that uses a sidewall-driven peristaltic micropump driven by pneumatic pressure. The adopted pump was integrated into a single-layer mold with a flow path and was simple to fabricate. Unlike syringe pumps, it not only pumps water forward, but also inhales from the back simultaneously, and can pump indefinitely. We developed a responsive and precise particle position control system using this pump in combination with a high-speed camera. In this system, the pumping pressure is operated by real-time adjustment of a pneumatic pressure supply to realize PID control. This approach moves the particle rapidly when it is far from a designated target position for a quick approach and slowly near the target position to position precisely.

Indexed as

microfluidic devicemicropumpposition controlsidewall-driven

Identifiers

PMID41753804
PMCPMC12942736

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.