Ocular biometry agreement among ZW-30, IOLMaster 700, and sirius in cataract patients.

Junjie Yang, Nijuan Yang, Yuying Xiang, Rui Li, Xuan Yu, Ling Jin, Yukan Huang

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Junjie YangDepartment of Ophthalmology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
Nijuan YangDepartment of Ophthalmology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
Yuying XiangDepartment of Ophthalmology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
Rui LiDepartment of Ophthalmology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
Xuan YuDepartment of Ophthalmology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
Ling JinDepartment of Ophthalmology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China. kingfishjin@126.com.
Yukan HuangDepartment of Ophthalmology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China. whuh_huangyk@163.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Accurate ocular biometry is crucial for the success of refractive cataract surgery. This study aims to assess the consistency and differences of a new biometer, the ZW-30, compared with the mainstream devices IOLMaster 700 and Sirius in patients with cataracts. A total of 307 patients with cataracts (603 eyes) were included. The anterior chamber depth (ACD), central corneal thickness (CCT), white-to-white (WTW) distance, pupil diameter (PD), flat K (K1), steep K (K2), corneal astigmatism (ΔK), total keratometry (TK), total corneal astigmatism (TCA), astigmatism axis, kappa angle (κ), axial length (AL), and lens thickness (LT) were measured using the ZW-30, IOLMaster 700, and Sirius. The consistency between devices was evaluated using Bland-Altman analysis, the correlation of parameters was assessed using Spearman correlation analysis, and inter-device agreement equations were established. Strong correlations (r ≥ 0.7) and no statistically significant differences in mean values (p > 0.05) were found for ACD, CCT, AL, LT, and anterior corneal curvature (K1/K2) among the three devices, but the 95% limits of agreement (LoA) exceeded the clinical threshold. Total corneal parameters (TK/TCA) and κ angle showed strong correlations (r ≥ 0.5) among the three devices, with significant inter-device differences in mean values (p < 0.05) and 95%LoA exceeding the clinical threshold. Corneal diameter (WTW) had a weak correlation (r = 0.48) between the ZW-30 and Sirius, and differences in PD measurement methods led to systematic bias. The ZW-30 is consistent with the IOLMaster 700 and Sirius in terms of group trends for basic biometric parameters (ACD/CCT/anterior corneal curvature), but significant individual differences exist (95%LoA exceeding the threshold). Total corneal parameters (TK/TCA) and κ angle require cross-validation with Sirius. WTW and PD are not interchangeable between devices due to differences in measurement principles. Cross-device parameter conversion should be avoided in clinical practice to ensure the accuracy of refractive surgery.

Indexed as

BiometryCataractAgedAged, 80 and overAnterior ChamberAstigmatismCataract ExtractionCorneaFemaleHumansMaleMiddle AgedAgreement assessmentBiometric measurementsCataractMeasurement discrepanciesZW-30 biometer

Identifiers

PMID41796175
PMCPMC13087307

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.