The Effect of Tear Film Stability on Variability of Posterior Corneal Curvature Readings with a Swept-Source Optical Biometer in Cataract Patients.

Maria Muzyka-Wozniak, Izabela Kaminska, Patrycja K Piwowarczyk, Dorota H Szczesna-Iskander

Abstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Maria Muzyka-WozniakResearch and Development Center CREO, Clinical Ophthalmology Center SPEKTRUM, Wroclaw, Poland.ORCID 0000-0002-4666-2400
Izabela KaminskaResearch and Development Center CREO, Clinical Ophthalmology Center SPEKTRUM, Wroclaw, Poland.ORCID 0009-0001-7094-7406
Patrycja K PiwowarczykDepartment of Biomedical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland.
Dorota H Szczesna-IskanderDepartment of Optics and Photonics, Wroclaw University of Science and Technology, Wroclaw, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To investigate the IOLMaster 700 variability of posterior curvature readings in relation to ocular surface parameters. Patients and Methods: Eligible cataract patients underwent two consecutive IOLMaster 700 exams and ocular surface assessments including non-invasive and fluorescein tear film break-up time (NIKBUT first and average, FBUT) during one preoperative visit. Intradevice repeatability was assessed based on within-subject standard deviation (Sw), test-retest variability (TRT), and intraclass correlation coefficient (ICC). The device composite standard deviation (SD) for biometric data, anterior corneal radii (R, R1, R2) and posterior corneal radii (PR, PR1, PR2) were analyzed in relation to ocular surface indices. Subgroup analysis evaluated the effect of FBUT on repeatability of trimmed-mean astigmatism vectors. Results: One hundred eyes of 67 patients were evaluated. Posterior keratometric indices had lower ICCs than anterior indices. The TRT for R and PR was 0.01 and 0.09 mm, respectively. The mean PR composite-SD was significantly higher than mean R composite-SD (34.49 vs 2.55 μm, respectively, p < 0.001, Conclusion: The OCT-based posterior curvature readings show greater variability than the telecentric anterior keratometry. Unlike anterior corneal measurements, posterior corneal readings variability was not linked to tear film parameters.

Indexed as

cataract surgeryposterior astigmatismposterior keratometrytear film break-up time

Identifiers

PMID41822531
PMCPMC12977991

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.