A backstepping control of artificial pancreas for type 1 diabetes based on sub-fixed-time stability.

Yuexian Xing, Hanjie Ma, Yongbo Zhang, Boyan Jiang, Kaiming Luo, Fei Hua

Abstract read
In one paragraph

Article in Frontiers in endocrinology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yuexian XingDepartment of Endocrinology, The Third Affiliated Hospital of Soochow University, Changzhou, Jiangsu, China.
Hanjie MaSchool of Information Science & Technology, Southwest Jiaotong University, Chengdu, Sichuan, China.
Yongbo ZhangSchool of Electrical and Information Engineering, Changzhou Institute of Technology, Changzhou, Jiangsu, China.
Boyan JiangSchool of Information Science & Technology, Southwest Jiaotong University, Chengdu, Sichuan, China.
Kaiming LuoDepartment of Endocrinology, The Third Affiliated Hospital of Soochow University, Changzhou, Jiangsu, China.
Fei HuaDepartment of Endocrinology, The Third Affiliated Hospital of Soochow University, Changzhou, Jiangsu, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: The artificial pancreas device is an automated control system that simulates the function of the human pancreas. It continuously infuses insulin into the body, thereby maintaining the blood glucose levels of diabetic patients within a safe range. This device is expected to be widely adopted for patients with type 1 diabetes in the future. Currently, research on artificial pancreas control methods is still in its early stages. Most existing blood glucose control methods rely on controller designs that incorporate only gain parameters and typically lack rigorous theoretical analysis of closed-loop system stability. In contrast, the Power Exponent Controller (PEC), which introduces power exponent parameters, belongs to the categories of finite-time or fixed-time control. These controllers often demonstrate superior overall performance in terms of convergence rate, robustness, and other critical control metrics. Methods: This paper proposes an insulin infusion rate based on PEC. A comprehensive stability analysis of the blood glucose closed-loop system is conducted using backstepping control theory, particularly providing mathematical expressions for system convergence time and steady-state error. The proposed control method is evaluated through three sets of simulation experiments comparing it with a traditional homogeneous control method. Results: The theoretical findings suggest that the proposed control method effectively reduces disturbances caused by meals and the infusion process, allowing quick adjustment of the patient's blood glucose to the target range. The results from the three sets of simulation experiments demonstrate that, compared to the traditional homogeneous control method, the proposed PEC scheme offers several advantages: a faster and more responsive reduction in hyperglycemia; the ability to consistently maintain postprandial glucose peaks below 180 mg/dL despite glucose fluctuations caused by three daily meals; and a reduction of approximately 25 minutes in the time required to bring blood glucose into the safe range during extreme daily regulation scenarios involving initial hyperglycemia. Discussion: These findings indicate that the proposed PEC method provides improved performance for artificial pancreas systems, with potential benefits for clinical management of type 1 diabetes.

Indexed as

Diabetes Mellitus, Type 1Hypoglycemic AgentsInsulinInsulin Infusion SystemsPancreas, ArtificialAlgorithmsBlood GlucoseComputer SimulationHumansBlood GlucoseHypoglycemic AgentsInsulinartificial pancreas controlblood glucose regulationpower exponent controlsub-fixed-time stabilitytype 1 diabetes