Evidence map›Paper›PMID 41847944›Full record

ArticleSmall (Weinheim an der Bergstrasse, Germany)2026

Micro-Texturized and Ultra-Soft Dry Electrode for Motion-Artifact Tolerant and Long-Term Stable Wearable Electrophysiological Monitoring.

Sang-Min Kim, Hee Jeong Jang, Ki-Hoon Kim, Yeon-Jeong Hwang, Yu Bin Lee, Joonsoo Jeong, Sunghoon Jung, Eubin Jeong, Dong-Wook Han, Eui-Suk Sung and 1 more

Abstract read
In one paragraph

Article in Small (Weinheim an der Bergstrasse, Germany), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Sang-Min KimDepartment of Information Convergence Engineering, College of Information & Biomedical Engineering, Pusan National University, Busan, Republic of Korea.ORCID https://orcid.org/0009-0008-4833-9405
Hee Jeong JangDepartment of Cogno-Mechatronics Engineering, College of Nanoscience & Nanotechnology, Pusan National University, Busan, Republic of Korea.
Ki-Hoon KimDepartment of Information Convergence Engineering, College of Information & Biomedical Engineering, Pusan National University, Busan, Republic of Korea.
Yeon-Jeong HwangDepartment of Information Convergence Engineering, College of Information & Biomedical Engineering, Pusan National University, Busan, Republic of Korea.
Yu Bin LeeDepartment of Information Convergence Engineering, College of Information & Biomedical Engineering, Pusan National University, Busan, Republic of Korea.
Joonsoo JeongDepartment of Information Convergence Engineering, College of Information & Biomedical Engineering, Pusan National University, Busan, Republic of Korea.
Sunghoon JungHUINNO Co., Ltd, Seoul, Republic of Korea.
Eubin JeongHUINNO Co., Ltd, Seoul, Republic of Korea.
Dong-Wook HanDepartment of Cogno-Mechatronics Engineering, College of Nanoscience & Nanotechnology, Pusan National University, Busan, Republic of Korea.
Eui-Suk SungDepartment of Otorhinolaryngology-Head and Neck Surgery, School of Medicine, Pusan National University, Yangsan, Republic of Korea.
Min-Ho SeoDepartment of Information Convergence Engineering, College of Information & Biomedical Engineering, Pusan National University, Busan, Republic of Korea.ORCID https://orcid.org/0000-0002-9990-9227

Funding

National Research Foundation of Korea (NRF) grant funded by the Korean government (MSIT) RS-2022-NR070445National Research Foundation of Korea (NRF) grant funded by the Korean government (MSIT) RS-2024-00406152Research Institute for Convergence of Biomedical Science and Technology, Pusan National University, Yangsan Hospital 20-2023-007
6 · The paper itself

Abstract

Accurate and robust acquisition of electrophysiological signals is essential for wearable healthcare and human-machine interface applications. However, conventional wet electrodes are limited by motion artifacts and insufficient long-term stability, while many dry electrodes lack adequate skin adhesion and mechanical compliance. Here, we present a carbon black (CB)-polydimethylsiloxane (PDMS) composite-based dry electrode featuring a micro-textured surface (R

Indexed as

Electrophysiological PhenomenaMotionWearable Electronic DevicesArtifactsDimethylpolysiloxanesElectrocardiographyElectrodesHumansHumidityMonitoring, PhysiologicSootWaterbaysilonDimethylpolysiloxanesSootWaterbiocompatible materialscarbon black compositesdry electrodeselectrophysiological monitoringmotion artifactsskin adhesionwearable sensors

Identifiers

PMID41847944
PMCPMC13173332

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.