Evidence map›Paper›PMID 41850323›Full record

ArticleJournal of bone metabolism2026

Cross-Calibration of Bone Mineral Density and Body Composition between GE Lunar Prodigy and Hologic Horizon W Dual Energy X-Ray Absorptiometry Systems.

Sujin Kim, Guen Young Lee, Jun-Il Yoo, Sang-Wook Lee, Yong-Chan Ha

Abstract read
In one paragraph

Article in Journal of bone metabolism, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Sujin KimDepartment of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Korea.
Guen Young LeeDepartment of Radiology, Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine, Gwangmyeong, Korea.
Jun-Il YooDepartment of Orthopedic Surgery, Inha University Hospital, Inha University School of Medicine, Incheon, Korea.
Sang-Wook LeeDepartment of Orthopedic Surgery, Busan Bumin Hospital, Busan, Korea.
Yong-Chan HaDepartment of Orthopedic Surgery, Seoul Bumin Hospital, Seoul, Korea.

Funding

Research of Korea Disease Control and Prevention Agency 2021-11-007
6 · The paper itself

Abstract

backgroundDual energy X-ray absorptiometry (DXA) measurements vary among instruments from different manufacturers. This study aimed to assess the correlation between bone mineral density (BMD) and body composition measured by the GE Lunar Prodigy and Hologic Horizon W DXA systems and to develop conversion equations.

methodsA total of 120 healthy volunteers (59 males, 61 females) aged 20 to 70 years were scanned on both DXA systems on the same day. BMD was measured at the lumbar spine (L1-L4) and bilateral femurs. Body composition parameters were measured for the whole body and regional sites. Bland-Altman analysis, Pearson correlation, and concordance correlation coefficient (CCC) were used to assess agreement. Linear regression was performed to derive conversion equations.

resultsThe Hologic system measured BMD values 14% to 20% lower at the lumbar spine and 8% to 17% lower at femoral sites compared to the GE Lunar system (all P<0.0001). Lean mass values were 4% to 10% lower on the Hologic system. Very strong correlations were observed for both BMD (r=0.944-0.980) and lean mass (r=0.963-0.984). Cross-calibration equations were developed for all measurement sites.

conclusionsDespite significant systematic differences, there was very high correlation between the two DXA systems. The conversion equations can facilitate comparison of measurements between these systems in clinical practice and research.

Indexed as

Absorptiometry, photonBody compositionBone densityCalibration

Identifiers

PMID41850323
PMCPMC13017167

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.