Evidence map›Paper›PMID 41851280›Full record

ArticleScientific reports2026

PSD-LW-DCN: a generalizable power spectral density based lightweight deep convolutional neural network for seizure detection.

Peipei Gu, Ming Zhang, Meiyan Xu, Duo Chen, Jibin Shou, Jiayang Guo, Naian Xiao

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Peipei Gu *College of Software Engineering, Zhengzhou University of Light Industry, Zhengzhou, 450000, China.
Ming Zhang *Department of Pediatrics, Zhongshan Hospital Xiamen University, Xiamen, 361005, China.
Meiyan XuDepartment of Computer Science and the Institute of Human Factors Engineering, Minnan Normal University, Zhangzhou, 363000, China.
Duo ChenSchool of Artificial Intelligence and Information Technology, Nanjing University of Chinese Medicine, Nanjing, 210023, China. 380013@njucm.edu.cn.
Jibin ShouCollege of Software Engineering, Zhengzhou University of Light Industry, Zhengzhou, 450000, China.
Jiayang GuoNational Institute for Data Science in Health and Medicine, Xiamen University, Xiamen, 361005, China.
Naian XiaoDepartment of Neurology, The Third Hospital of Xiamen, Xiamen, 361100, China. wsxna@163.com.

Funding

the National Natural Science Funds of China 62006100
6 · The paper itself

Abstract

Objective: Cross-subject generalization in EEG-based seizure detection remains a significant challenge due to diverse physiological differences among patients, which can degrade model performance across individuals. This work aims to develop a robust, lightweight, and fast-deployable model for cross-subject seizure detection that achieves high accuracy while enabling real-time, low-latency inference on resource-constrained devices. Methods: We propose PSD-LW-DCN, a novel lightweight deep convolutional network that leverages power spectral density (PSD) features extracted via multitaper spectral estimation. Raw EEG signals are preprocessed through bandpass filtering, segmentation, and class balancing. PSD features are computed across multiple frequency bands (δ,θ,α,β,γ), averaged across channels to enhance generalizability, and concatenated as input to the network. The model was trained and evaluated separately on the CHB-MIT and TUSZ datasets, with no data mixing between them. Results: With only 61,218 parameters, PSD-LW-DCN achieves state-of-the-art efficiency, reducing inference time to 1.9 ms/sample on CHB-MIT and 2.1 ms/sample on TUSZ, demonstrating its suitability for real-time applications. It attains 85.84% accuracy on CHB-MIT and 83.21% on TUSZ, representing improvements of 5% and 3%, respectively, over previous approaches. Notably, the model shows strong cross-subject generalization and robustness across diverse patient populations. In clinically meaningful event-based evaluation, it achieves a low false alarm rate of 0.33 false alarms per hour (FA/h) on CHB-MIT and 1.09 FA/h on TUSZ, indicating high operational reliability in long-term monitoring scenarios. Conclusions: PSD-LW-DCN offers an optimal balance between accuracy, speed, and model size, making it highly suitable for real-time, edge-based clinical diagnosis of epilepsy. Its efficiency and low false alarm burden confirm its potential for deployment in low-power wearable and point-of-care systems. Future work will focus on further reducing the false alarm rate, particularly in more heterogeneous datasets like TUSZ, to enhance clinical usability.

Indexed as

ElectroencephalographySeizuresAlgorithmsConvolutional Neural NetworksHumansSignal Processing, Computer-AssistedCross-subjectEEGPower spectral densitySeizure detection

Identifiers

PMID41851280
PMCPMC13136392

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.