Evaluation of the accuracy of cone-beam CT-based dose calculation for target volumes and organs at risk in left-sided breast cancer radiotherapy.

Xiaoxiao Hou, Zhenglu Bai, Xiaoxiao Jin, Erxun Dai, Yaqi Jiang, Jun Ma, Jun Li

Abstract read
In one paragraph

Article in Frontiers in oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xiaoxiao HouRadiotherapy Center, Northern Jiangsu People's Hospital, Yangzhou, Jiangsu, China.
Zhenglu BaiRadiotherapy Center, Northern Jiangsu People's Hospital, Yangzhou, Jiangsu, China.
Xiaoxiao JinRadiotherapy Center, Northern Jiangsu People's Hospital, Yangzhou, Jiangsu, China.
Erxun DaiRadiotherapy Center, Northern Jiangsu People's Hospital, Yangzhou, Jiangsu, China.
Yaqi JiangRadiotherapy Center, Northern Jiangsu People's Hospital, Yangzhou, Jiangsu, China.
Jun MaRadiotherapy Center, Northern Jiangsu People's Hospital, Yangzhou, Jiangsu, China.
Jun LiRadiotherapy Center, Northern Jiangsu People's Hospital, Yangzhou, Jiangsu, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Accurate dose calculation is essential in breast cancer radiotherapy. This study aimed to evaluate the feasibility and accuracy of cone-beam CT (CBCT) images with HU-relative electron density (HU-RED) correction for dose calculation in left-sided breast cancer radiotherapy. Methods: Twenty postoperative patients receiving adjuvant radiotherapy at Subei People's Hospital of Jiangsu Province (Yangzhou, China) from January 2022 to December 2024 were retrospectively enrolled. A patient-specific HU-RED calibration curve was generated using an improved density override method. Treatment plans created on planning CT (pCT) were transferred to CBCT for dose recalculation with identical optimization parameters. Dosimetric parameters of the planning target volume (PTV) and organs at risk (OARs) were compared. Two-dimensional gamma analysis was performed to assess dose consistency. Equivalence between CBCT- and pCT-based dose calculations was further evaluated using the two one-sided tests (TOST), Lin's concordance correlation coefficient (CCC), intraclass correlation coefficient (ICC), and Bland-Altman analysis. Results: Differences in PTV dosimetric indices (D2, D50, D98, Dmean, HI, CI) between CBCT- and pCT-based plans were small, with mean deviations <1.3% and no statistically significant differences ( Discussion: CBCT images corrected with HU-RED calibration achieved highly consistent dose calculation results compared with pCT in left-sided breast cancer radiotherapy. This method is feasible for clinical dose verification and may support future adaptive radiotherapy strategies, particularly with the integration of artificial intelligence techniques.

Indexed as

breast cancercone-beam CTdosimetric evaluationorgans at riskradiotherapy

Identifiers

PMID41858368
PMCPMC12996974