Evidence map›Paper›PMID 41892133›Full record

ArticleBiomimetics (Basel, Switzerland)2026

Hyper-Thyro Vision: An Integrated Framework for Hyperthyroidism Diagnostic Facial Image Analysis Based on Deep Learning.

Poonyisa Thepmangkorn, Suchada Sitjongsataporn

Abstract read
In one paragraph

Article in Biomimetics (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Poonyisa ThepmangkornThe Electrical Engineering Graduate Program, Faculty of Engineering and Technology, Mahanakorn University of Technology, Nongchok, Bangkok 10530, Thailand.ORCID 0009-0006-0877-8388
Suchada SitjongsatapornDepartment of Electronic Engineering, School of Electrical and Electronic Engineering (SEE), Mahanakorn University of Technology, Nongchok, Bangkok 10530, Thailand.ORCID 0000-0002-2357-2365

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents an integrated multi-modal framework for detecting hyperthyroidism-associated abnormalities, namely exophthalmos and thyroid-related neck swelling, through the joint analysis of frontal facial and neck images using a deep learning-based approach. The objective of this research is to develop an integrated AI framework that improves hyperthyroid-related abnormality detection by simultaneously analyzing facial images of both the eye and neck based on pattern clinical knowledge. The multi-modal framework mimics a biological visual mechanism by using a dual-pathway architecture that concurrently processes foveal-like details of the eyes and neck. It integrates these high-resolution visual embeddings with quantitative morphological measurements to simulate a clinician's ability to fuse observation with physical assessment. The proposed system employs a multi-faceted decision-making process derived from three distinct data components: two from frontal face analysis and one from neck region analysis. Specifically, eye regions extracted from facial images are preprocessed using the YOLOv11s model. The proposed system leverages a dual-pathway processing architecture to extract comprehensive diagnostic features. For the eye dataset, the framework utilizes a face mesh-based eye landmark (FMEL) to extract both eye regions and perform eyes unfold processing. These regions are subsequently analyzed by the proposed sclera map unwrapping engine (SMUE) to derive quantitative sclera metrics from both the left and right eyes. To optimize classification, a dual-branch architecture is employed by integrating CNN visual embeddings with SMUE-derived statistical features through a feature fusion layer. Simultaneously, the neck processing path executes the neck region of interest (ROI) prediction {upper, lower} to segment critical regions for goiter assessment via the proposed neck μ-σ ensemble thresholding (NSET) algorithm. The experimental results demonstrate that the proposed algorithm for eye analysis achieved a mean average precision (mAP50) of 96.4%, with a specific mAP50 of 98.6% for the hyperthyroid class. Regarding quantitative scleral measurement, the SMUE process revealed distinct morphological differences, with the experimental data group exhibiting consistently higher pixel distances across the reference points compared with the normal group. Furthermore, the proposed NSET algorithm yielded the highest performance for swollen neck classification with an mAP50 of 92.0%, significantly outperforming the baseline deep learning models while maintaining lower computational complexity.

Indexed as

artificial intelligence (AI)deep learningexophthalmosfacial imagesfeature fusiongoiterhyperthyroidismmulti-modal framework

Identifiers

PMID41892133
PMCPMC13024728

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.