Evidence map›Paper›PMID 41892716›Full record

ArticleJournal of cardiovascular development and disease2026

Muscular VSD Device Complications: Literature Review and Possible Implications for Echocardiographic Follow-Up.

Micah Tatum, Thomas Casto, Amulya Buddhavarapu, Elizabeth Lyman, Alison Gehred, Benjamin Blais, Clifford L Cua

Abstract read
In one paragraph

Article in Journal of cardiovascular development and disease, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Micah TatumHeart Center, Nationwide Children's Hospital, 700 Children's Drive, Columbus, OH 43205, USA.
Thomas CastoHeart Center, Nationwide Children's Hospital, 700 Children's Drive, Columbus, OH 43205, USA.ORCID 0009-0005-9409-6377
Amulya BuddhavarapuHeart Center, Nationwide Children's Hospital, 700 Children's Drive, Columbus, OH 43205, USA.
Elizabeth LymanHeart Center, Nationwide Children's Hospital, 700 Children's Drive, Columbus, OH 43205, USA.ORCID 0000-0002-3363-0506
Alison GehredHeart Center, Nationwide Children's Hospital, 700 Children's Drive, Columbus, OH 43205, USA.ORCID 0000-0002-1832-6725
Benjamin BlaisHeart Center, Nationwide Children's Hospital, 700 Children's Drive, Columbus, OH 43205, USA.ORCID 0000-0003-1929-3096
Clifford L CuaHeart Center, Nationwide Children's Hospital, 700 Children's Drive, Columbus, OH 43205, USA.ORCID 0000-0002-9172-3874

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Long-term transthoracic echocardiogram (TTE) follow-up guidelines after muscular ventricular septal defect (mVSD) device closure are vague. The primary goal of this study was to perform a literature search to characterize the type and timing of complications that occur after mVSD device placement. The search was performed in Medline (PubMed) with English language and publication date (1983 to 2024) filters applied. Studies were included if they reported on patients who underwent mVSD device closure. Studies were excluded if they reported on other types of ventricular septal defect (VSD) device closures, were review papers, or did not report outcomes after the device procedure. A total of 139 articles met the criteria (retrospective, n = 63; prospective, n = 10; case reports, n = 66), encompassing 1668 patient cases. Age at the time of mVSD closure was 10.6 + 2.7 years. Incidence of complications was 17.9% (299/1668). Maximum follow-up was 160 months. Most complications were residual shunts (40.8%, 122/299), followed by valve dysfunction (13.7%, 41/299) and arrhythmias (13.7% 41/299). The vast majority of complications occurred ≤12 months post-device placement 98.0% (293/299). Only 1.3% (4/299) of complications occurred at >12 months (mild tricuspid regurgitation, n = 2; left bundle branch block, n = 1; atrial fibrillation, n = 1). Time until complication was not reported in 0.7% (2/299) of patients (residual shunts, n = 2). All clinically significant complications diagnosed via TTE occurred <12 months post-mVSD device procedure. The utility of repeat TTE beyond one year after mVSD device closure should be reassessed if no clinical concerns are present.

Indexed as

cardiac catheterizationmuscular ventricular septal defectventricular septal defect

Identifiers

PMID41892716
PMCPMC13026746

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.