Evidence map›Paper›PMID 41910848›Full record

ArticleMedical & biological engineering & computing2026

Does FNS outperform CCS in Pauwel's type III fracture fixation: a combined experimental and numerical study.

Laureb Rao, Samarth Mittal, Apoorva Kabra, Vivek Trikha, Anoop Chawla, Kaushik Mukherjee

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Laureb RaoTransportation Research and Injury Prevention Centre, Indian Institute of Technology Delhi, New Delhi, India.
Samarth MittalDepartment of Orthopaedics, Jai Prakash Narayan Apex Trauma Centre, All India Institute of Medical Sciences, New Delhi, India.
Apoorva KabraDepartment of Orthopaedics, Jai Prakash Narayan Apex Trauma Centre, All India Institute of Medical Sciences, New Delhi, India.
Vivek TrikhaDepartment of Orthopaedics, Jai Prakash Narayan Apex Trauma Centre, All India Institute of Medical Sciences, New Delhi, India.
Anoop ChawlaDepartment of Mechanical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi, 110016, India.
Kaushik MukherjeeDepartment of Mechanical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi, 110016, India. kmukherjee@mech.iitd.ac.in.ORCID http://orcid.org/0000-0002-8290-2803

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Open reduction and internal fixation (ORIF) is the gold standard for fixing femoral neck fractures in young patients. Traditionally, Cannulated Cancellous Screws (CCS) are used in such cases, while the newer Femoral Neck System (FNS) offers dynamic compression with minimal implant footprint. The current study compares the biomechanical performances of CCS and FNS implants for Pauwels type III fracture fixation through a combined FE and experimental evaluation using composite femurs. The material property of cortical bone samples was first characterized using three-point bend tests and nano-indentation. The average Young’s modulus obtained from three-point bend tests was 6.76 ± 1.20 GPa, and from the nano-indentation tests was 6.29 ± 1.46 GPa. Under a compressive load of 800 N, the maximum observed vertical displacements in the intact bone, the bones fixed with CCS, and FNS were approximately 0.94 mm, 1.26 mm, and 2.00 mm, respectively. The FE-predicted values were in close agreement with the experimental values (R ≈ 0.99, p < 0.01). Under physiological loading of normal walking, the FE-predicted maximum von Mises stress in FNS (535 MPa) was higher than CCS (344 MPa). In the CCS fixation, the highest stress was observed near the fracture plane of the bone, whereas for the FNS fixation, the maximum stress was located in the cortical screw adjacent to the sideplate. The results from the current study have shown that the new implant system, FNS, does not outperform CCS fixation from a biomechanical perspective.

Indexed as

Bone ScrewsFemoral Neck FracturesFracture Fixation, InternalBiomechanical PhenomenaElastic ModulusFemur NeckFinite Element AnalysisHumansStress, MechanicalCannulated cancellous screwsFemoral neck fracturesFemoral neck systemPauwels type III fracture

Identifiers

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.