Evidence map›Paper›PMID 41938587›Full record

ArticleCommunications physics2026

De-aberration for noninvasive transcranial photoacoustic computed tomography through an adult human skull.

Yousuf Aborahama, Karteekeya Sastry, Manxiu Cui, Yang Zhang, Yilin Luo, Rui Cao, Geng Ku, Jigmi Basumatary, Junhao Zhu, Siying Kong and 1 more

Abstract read
In one paragraph

Article in Communications physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

11 authors.

Yousuf Aborahama *Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 USA.ORCID 0000-0002-9527-8923
Karteekeya Sastry *Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 USA.ORCID 0000-0001-7659-4878
Manxiu Cui *Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 USA.
Yang ZhangCaltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 USA.
Yilin LuoCaltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 USA.ORCID 0000-0002-4611-3049
Rui CaoCaltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 USA.
Geng KuCaltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 USA.
Jigmi BasumataryCaltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 USA.
Junhao ZhuCaltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 USA.
Siying KongCaltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 USA.
Lihong V WangCaltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125 USA.ORCID 0000-0001-9783-4383

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Noninvasive transcranial photoacoustic computed tomography (PACT) of the human brain, despite its clinical potential as a complementary technology to functional MRI, remains impeded by the acoustic distortion induced by the human skull. The distortion, which is attributed to the markedly different material properties of the skull relative to soft tissue, results in heavily aberrated PACT images. Herein, we report an experimental demonstration of the de-aberration of PACT images through an ex-vivo adult human skull using a homogeneous elastic model for the skull. Using only the geometry, position, and orientation of the skull, obtained from adjunct imaging data and fiducial markers, we faithfully de-aberrate the PACT images of light-absorbing phantoms acquired through an ex-vivo human skull for different levels of phantom complexity and positions. We also demonstrate the generality of our results by attaining a similar extent of de-aberration through a second ex-vivo human skull. Our work addresses the longstanding challenge of skull-induced aberrations in transcranial PACT and advances the field towards unlocking the full potential of transcranial human brain PACT.

Indexed as

AcousticsPhotoacoustics

Identifiers

PMID41938587
PMCPMC13043303

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.