Evidence map›Paper›PMID 41939160›Full record

ArticleJournal of medical physics

Design and Optimization of Collimator for Preclinical Single-photon Emission Computed Tomography Scanner: A Monte Carlo Study.

Mohammad Mirdoraghi, Behnoosh Teimourian Fard, Olga Kochebina, Hojjat Mahani, Mohammad Reza Ay

Abstract read
In one paragraph

Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Mohammad MirdoraghiDepartment of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
Behnoosh Teimourian FardResearch Center for Molecular and Cellular Imaging (RCMCI), Advanced Medical Technologies and Equipment Institute (AMTEI), Tehran University of Medical Sciences (TUMS), Tehran, Iran.
Olga KochebinaBioMaps Laboratory, University Paris-Saclay, Frédéric Joliot Hospital Service, CEA, Orsay, France.
Hojjat MahaniRadiation Applications Research School, Nuclear Science and Technology Research Institute, Tehran, Iran.
Mohammad Reza AyDepartment of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Small animal imaging has an extensive variety of applications, including the design and optimization of novel imaging devices. Monte Carlo (MC) simulations are enhanced due to their high accuracy. The purpose of this investigation was to implement and validate a MC model for a preclinical single-photon emission computed tomography (SPECT) known as high-resolution SPECT II (HiReSPECT II) machine developed in our laboratory and also optimize different collimator materials and geometries for improving the sensitivity and spatial resolution. Materials and Methods: The validation of a small animal SPECT scanner equipped with lead hexagonal parallel-hole collimator, CsI (Na) pixelated crystal, and SiPM photodiodes was performed by comparing experimental results with Geant4 application for tomography emission (GATE) simulation data. In the next step, the optimization appraisals for both spatial resolution and sensitivity on the collimator material (W and Pb) and hole diameter were carried out using GATE. The experimental and simulated sensitivities were obtained using a cylindrical phantom at source to the collimator distance (SCD) of 3 cm. Moreover, a line source was applied to assess the spatial resolution in the simulated and experimental environments at different SCDs. Besides, a tungsten collimator with a hole diameter of 0.99 mm is suggested. Results: The discrepancy between experimental and simulated sensitivities was <3%. In addition, the differences between simulated and experimental spatial resolutions were about 5%. Furthermore, the optimized hole diameter for tungsten is 0.99 mm according to the curve representing the tradeoff between spatial resolution and sensitivity. Conclusion: Lead exhibits a little higher sensitivity compared to tungsten because it has superior penetration and scattering abilities, leading to an increased full width at the tenth maximum that can diminish the spatial resolution. In addition, enlarging the diameter of the holes increases the number of photons that penetrate and scatter, thereby reducing the spatial resolution. The proposed collimator is able to provide adequate sensitivity considering the spatial resolution achieved at the SCD of 3 cm.

Indexed as

Collimator designgeant4 application for tomography emissionhigh-resolution single-photon emission computed tomography IIsimulationssingle-photon emission computed tomography

Identifiers

PMID41939160
PMCPMC13046183

What Socratic holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.