Evidence map›Paper›PMID 41978050›Full record

ArticleSensors (Basel, Switzerland)2026

A Cheonjiin Layout Mental Speller: Developing a Simple and Cost-Effective EEG-Based Brain-Computer Interface System.

Ji Won Ahn, Gi Yeon Yu, Seong-Wan Kim, Young-Seek Seok, Kyung-Min Byun, Seung Ho Choi

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ji Won AhnDepartment of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea.
Gi Yeon YuDepartment of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea.
Seong-Wan KimDepartment of Agricultural Biology, National Institute of Agricultural Sciences, Rural Development Administration, Wanju 55365, Republic of Korea.
Young-Seek SeokGangwon-do Agricultural Product Registered Seed Station, Chuncheon 24410, Republic of Korea.
Kyung-Min ByunDepartment of Biomedical Engineering, College of Electronics and Information, Kyung Hee University, Yongin 17104, Republic of Korea.
Seung Ho ChoiDepartment of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea.

Funding

Ministry of Science and ICT IITP-2026-RS-2024-00438239Rural Development Administration RS-2026-25519175
6 · The paper itself

Abstract

A brain-computer interface (BCI) enables direct communication between the brain and external devices by translating neural activity into executable control commands. Among electroencephalography (EEG)-based paradigms, steady-state visual evoked potential (SSVEP) is widely adopted due to its high signal-to-noise ratio, robustness, and minimal calibration requirements. While SSVEP-based spellers have been extensively investigated, many existing systems rely on high-channel-density EEG recordings and computationally complex processing pipelines, and are primarily designed for alphabetic input structures. In this study, we present an SSVEP-based Korean speller that integrates the Cheonjiin keyboard layout to support intuitive composition of Hangul syllables. The proposed system adopts a simple configuration, employing only five visual stimulation frequencies (6.67-12 Hz) and two occipital EEG channels (O1 and O2), with real-time frequency recognition performed using canonical correlation analysis (CCA) within a 1.5 s sliding window. EEG signals were acquired at 200 Hz using an OpenBCI Ganglion board, band-pass filtered (5-45 Hz), and processed with harmonic sinusoidal reference templates for multi-frequency classification. The proposed interface generates five control commands (up, down, left, right, and select), enabling directional cursor navigation and character confirmation on a 4 × 4 virtual Cheonjiin keyboard. Experimental validation with three healthy participants demonstrated an average classification accuracy of approximately 82% and an information transfer rate (ITR) of 31.2 bits/min. Frequency-domain analysis revealed clear spectral peaks at the stimulation frequencies and their harmonics, indicating reliable SSVEP responses. The proposed system employs a simple two-channel configuration integrated with a Korean language-specific input structure, demonstrating that reliable SSVEP-based communication can be realized without computationally intensive algorithms or high-cost EEG acquisition systems. These findings demonstrate that reliable SSVEP-based communication can be achieved using a low-channel configuration without reliance on high-cost EEG equipment.

Indexed as

Brain-Computer InterfacesElectroencephalographyCost-Benefit AnalysisEvoked Potentials, VisualHumansSignal Processing, Computer-Assistedbrain–computer interface (BCI)Cheonjiin keyboarddirectional inputelectroencephalography (EEG)speller system

Identifiers

PMID41978050
PMCPMC13075287

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.