Observational studyMedicine2026
Effect of caudal block injection speed on optic nerve sheath diameter in pediatric surgeries: A prospective observational cohort study.
Observational study in Medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Perioperative pain management in children is challenging due to limited communication and the risk of long-term psychological effects. Regional anesthesia, particularly the caudal block (CB), is frequently used in pediatric surgery for lower abdominal and urogenital procedures. However, the influence of injection speed during CB on intracranial and hemodynamic responses remains unclear. This prospective observational cohort study included 64 pediatric patients (American Society of Anesthesiologists I-II, aged 1-7 years) undergoing elective lower abdominal or urogenital surgery under general anesthesia. All patients received a CB with 0.8 mL/kg of 0.125% bupivacaine. Injection speed was not assigned by the study protocol but reflected routine clinical practice, and patients were categorized according to the injection speed used (0.25 mL/s or 0.5 mL/s). The primary outcome was the change in optic nerve sheath diameter (ONSD) over time and between injection-speed groups. Secondary outcomes included heart rate and mean arterial pressure, recorded at baseline and at predefined time points after the block. Baseline ONSD values were similar between groups. ONSD increased transiently after caudal injection in both groups, with a significantly greater increase in the fast-injection group immediately after the block. These differences were short-lived, and ONSD values returned toward baseline within 10 to 20 minutes, with no persistent intergroup differences. Heart rate and mean arterial pressure showed mild, transient reductions in both groups, which were slightly more pronounced in the fast-injection group but remained within physiological limits. Different caudal injection speeds were associated with distinct transient changes in ONSD and hemodynamic parameters. Slower injection was associated with more gradual physiological responses during the early postinjection period.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.