Evidence map›Paper›PMID 42009306›Full record

ArticleAnalytical chemistry2026

Cryo-HIM-SIMS on the npSCOPE: Correlative Topographic, Transmitted and SIMS Imaging at Cryogenic Temperatures.

Tatjana Taubitz, Olivier De Castro, Dustin Andersen, Zahraa Berro, Sukriti Hans, Saba Tabean, Moritz Wachsmuth-Melm, Gerhard Hobler, Inge Nelissen, Falk Lucas and 5 more

Abstract read
In one paragraph

Article in Analytical chemistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Tatjana TaubitzAdvanced Instrumentation for Nano-Analytics (AINA), Scientific Instrumentation and Process Technology, Luxembourg Institute of Science and Technology, 4422 Belvaux, Luxembourg.
Olivier De CastroAdvanced Instrumentation for Nano-Analytics (AINA), Scientific Instrumentation and Process Technology, Luxembourg Institute of Science and Technology, 4422 Belvaux, Luxembourg.ORCID 0000-0001-9968-6695
Dustin AndersenAdvanced Instrumentation for Nano-Analytics (AINA), Scientific Instrumentation and Process Technology, Luxembourg Institute of Science and Technology, 4422 Belvaux, Luxembourg.
Zahraa BerroAdvanced Instrumentation for Nano-Analytics (AINA), Scientific Instrumentation and Process Technology, Luxembourg Institute of Science and Technology, 4422 Belvaux, Luxembourg.
Sukriti HansAdvanced Instrumentation for Nano-Analytics (AINA), Scientific Instrumentation and Process Technology, Luxembourg Institute of Science and Technology, 4422 Belvaux, Luxembourg.
Saba TabeanAdvanced Instrumentation for Nano-Analytics (AINA), Scientific Instrumentation and Process Technology, Luxembourg Institute of Science and Technology, 4422 Belvaux, Luxembourg.
Moritz Wachsmuth-MelmDepartment of Infectious Diseases-Virology, Medical Faculty, Heidelberg University, 69120 Heidelberg, Germany.
Gerhard HoblerInstitute of Solid-State Electronics, Technische Universität Wien, 1040 Wien, Austria.
Inge NelissenEnvironmental Intelligence, Vlaamse Instelling voor Technologisch Onderzoek (VITO), 2400 Mol, Belgium.
Falk LucasScopeM, ETH Zürich, 8093 Zürich, Switzerland.
Santhana EswaraAdvanced Instrumentation for Nano-Analytics (AINA), Scientific Instrumentation and Process Technology, Luxembourg Institute of Science and Technology, 4422 Belvaux, Luxembourg.ORCID 0000-0003-4151-2304
Petr ChlandaDepartment of Infectious Diseases-Virology, Medical Faculty, Heidelberg University, 69120 Heidelberg, Germany.
Tom WirtzAdvanced Instrumentation for Nano-Analytics (AINA), Scientific Instrumentation and Process Technology, Luxembourg Institute of Science and Technology, 4422 Belvaux, Luxembourg.
Jean-Nicolas AudinotAdvanced Instrumentation for Nano-Analytics (AINA), Scientific Instrumentation and Process Technology, Luxembourg Institute of Science and Technology, 4422 Belvaux, Luxembourg.ORCID 0000-0002-4966-7653
Antje BiesemeierAdvanced Instrumentation for Nano-Analytics (AINA), Scientific Instrumentation and Process Technology, Luxembourg Institute of Science and Technology, 4422 Belvaux, Luxembourg.ORCID 0000-0002-3462-8803

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Multimodal helium ion microscopy (HIM) and secondary ion mass spectrometry (SIMS) provide in situ spatial imaging and chemical analysis at nanoscale resolution. Operation at cryogenic temperatures is needed to overcome artifacts related to sample preparation and beam damage during analysis of beam-sensitive samples (including frozen-hydrated specimens). Here, we present a gas field ion source HIM, the "npSCOPE", that was retrofitted with a liquid nitrogen-cooled copper-shielded instrument chamber and a 5-axis cryo-sample stage. A dedicated liquid nitrogen-cooled ultrahigh vacuum sample transfer system paired with a humidity-controlled cryo-glovebox reducing contamination complements the setup for analysis of frozen-hydrated samples. Thanks to its three detection modalities - secondary electron (SE) imaging, chemical analysis based on an integrated double-focusing magnetic sector SIMS system and scanning transmission ion microscopy (STIM) - this prototype allows for correlative topographic, volumetric and chemical imaging under room temperature (RT) and cryogenic conditions. No significant ice buildup or edge effects were observed when monitoring samples over 36 h at < -139 °C. Cryo-SE imaging confirmed reduced beam-induced modification of beam-sensitive silica-coated gold nanoparticles, and cryo-STIM imaging on a polycrystalline gold foil showed a 34% average improved ion transmission signal intensity as compared to RT. The full cryo-transfer and analysis workflow was successfully tested on cryo-lamellae of plunge-frozen cells prepared by cryo-focused Gallium ion beam milling (cryo-FIB), providing proof-of-principle confirmation for correlative cryo-analysis at the nanoscale. In conclusion, correlative cryo-ion-beam imaging and analysis is a promising solution for nanoscale, multimodal investigations of both close-to-native biological and other beam-sensitive materials.

Indexed as

Cold TemperatureHeliumMicroscopySpectrometry, Mass, Secondary IonHelium

Identifiers

PMID42009306
PMCPMC13150799

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.