Evidence map›Paper›PMID 42039733›Full record

ArticleJournal of medical physics

Feasibility of Magnetic Resonance-based Synthetic Computed Tomography for Proton Dose Calculation in Prostate Cancer.

Napatsorn Thumyongkit, Chanon Puttanawarut, Sithiphong Suphaphong, Ladawan Worapruekjaru, Pareena Earwong, Sawwanee Asavaphatiboon, Nauljun Stansook, Suphalak Khachonkham

Abstract read
In one paragraph

Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Napatsorn ThumyongkitMaster of Science Program in Medical Physics, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
Chanon PuttanawarutChakri Naruebodindra Medical Institute, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Samut Prakan, Thailand.
Sithiphong SuphaphongDepartment of Diagnostic and Therapeutic Radiology, Division of Radiation Oncology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
Ladawan WorapruekjaruDepartment of Diagnostic and Therapeutic Radiology, Division of Radiation Oncology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
Pareena EarwongMaster of Science Program in Medical Physics, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
Sawwanee AsavaphatiboonDepartment of Diagnostic and Therapeutic Radiology, Division of Diagnostic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
Nauljun StansookDepartment of Diagnostic and Therapeutic Radiology, Division of Radiation Oncology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
Suphalak KhachonkhamDepartment of Diagnostic and Therapeutic Radiology, Division of Radiation Oncology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aims: This study evaluates the feasibility of deep learning-generated synthetic computed tomography (sCT) for proton dose calculation. Materials and Methods: The sCT images were generated from T2-weighted magnetic resonance imaging (MRI) of 10 retrospectively collected prostate cancer patients using MRI Planner (Spectronic Medical, Sweden). The sCT images were compared with CT images to assess image quality, proton range, and dosimetric evaluation. Image quality was evaluated using mean Hounsfield unit (HU) difference, mean absolute error (MAE), and mean error. Geometric agreement between CT and sCT images was measured using the dice similarity coefficient (DSC). Ground truth CT images were employed to generate single-field uniform dose (SFUD) and intensity-modulated proton therapy plans for each patient. The proton range shift (RS) between CT and sCT images was calculated at the central 80% distal dose falloff in each SFUD plan. Dosimetric evaluations were performed using dose-volume histogram comparison and gamma index analysis. Results: The mean MAE values for the body, bone, and soft tissue were 43.42 ± 3.96, 118.40 ± 9.70, and 33.90 ± 4.04 HU, respectively. DSC values revealed good geometric agreement between sCT and CT images. All RS values fell within clinically acceptable criteria, with a relative RS ranging from 0.02%-0.67%. The relative dose differences for all clinical target volume metrics were less than ±1.0%, and gamma pass rates exceeded 90% at 3%/3 mm, 3%/2 mm, and 2%/2 mm criteria. Conclusion: sCT images generated by MRI Planner were feasibly used for proton dose calculation in prostate cancer and could potentially be used for implementing MRI-only proton therapy.

Indexed as

Dosimetric comparisonmagnetic resonance imagingproton dose calculationproton rangesynthetic computed tomography

Identifiers

PMID42039733
PMCPMC13105386

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.