Evidence map›Paper›PMID 42069688›Full record

ArticleScientific reports2026

An enhanced novel surface plasmon resonance sensor employing perovskite nanomaterial and bismuth ferrite to identify different ethanol concentrations.

Malek G Daher, Mostafa R Abukhadra, Samer M Srour, Emad Solouma, Stefano Bellucci, Haifa A Alqhtani, Hussein A Elsayed, Ahmed Mehaney

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Malek G DaherPhysics Department, Islamic University of Gaza, P.O. Box 108, Gaza, Palestine. malekjbreel20132017@gmail.com.
Mostafa R AbukhadraGeosciences Department, College of Science, United Arab Emirates University, Al Ain, 15551, United Arab Emirates. m.abdelwahab@uaeu.ac.ae.
Samer M SrourPhysics Department, Islamic University of Gaza, P.O. Box 108, Gaza, Palestine.
Emad SoloumaDepartment of Mathematics and Statistics, College of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh, 11623, Saudi Arabia.
Stefano BellucciINFN-Laboratori Nazionali di Frascati, Vie. E. Fermi 54, Frascati, 00044, Italy.
Haifa A AlqhtaniDepartment of Biology, College of Science, Princess Nourah bint Abdulrahman University, P.O. BOX 84428, Riyadh, 11671, Saudi Arabia.
Hussein A ElsayedPhotonic and Phononic Crystals Lab, Physics Department, Faculty of Science, Beni-Suef University, Beni-Suef, 62512, Egypt.
Ahmed MehaneyPhotonic and Phononic Crystals Lab, Physics Department, Faculty of Science, Beni-Suef University, Beni-Suef, 62512, Egypt.

Funding

Princess Nourah bint Abdulrahman University Project number (PNURSP2025R458), Princess Nourah bint Abdulrahman University, Riyadh, Saudi Arabia.
6 · The paper itself

Abstract

This study presents a novel surface plasmon resonance (SPR) biosensor composed of silver (Ag), bismuth ferrite (BiFeO3), nickel (Ni), and perovskite nanomaterial (MAPbBr3). Different ethanol concentrations (ECs) could be detected thanks to the hybrid structure. The transfer matrix technique (TMM) is used to assess the suggested surface plasmon resonance (SPR) structure. To compare the angular sensitivity of the EC = 0% sample with the EC = 10% to 40% sample, a comparative analysis was carried out. The BiFeO3, Ni, and MAPbBr3 layer thicknesses must be changed in order to maximize the surface plasmon resonance (SPR) structure's performance. Additionally, precise measurements of the resonance angle (θ_res), minimum reflectance (Rmin), full width at half maximum (FWHM), and figure of merits (FOM) have been made. In comparison to the conventional structure (BK7/Ag/SM) with a matching FOM of 149.12 RIU-1, the ideal angular sensitivity was found to be 55 nm for Ag, 5 nm for BiFeO3, 20 nm for Ni, and 3 nm of MAPbBr3 with a sensitivity of 428 Degree RIU-1, which improved by 268.96%. Furthermore, the impacts of four sensor structures-conventional (BK7/Ag/SM), with BiFeO3 (BK7/Ag/BiFeO3/SM), with Ni (BK7/Ag/BiFeO3/Ni/SM), and our suggested sensor structure (BK7/Ag/BiFeO3/Ni/MAPbBr3/ SM) on sensitivity were examined in this work. The proposed structure shows better angular sensitivity compared to the existing surface plasmon resonance (SPR) biosensor. The biosensor in question shows promise for identifying a broad variety of chemical molecules and biological analytes because of its increased sensitivity.

Indexed as

BiFeO3BiosensorEthanolPerovskiteSensitivitySPR

Identifiers

PMID42069688
PMCPMC13287815

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.